Roof pitch insulation
Since locating our new central heating boiler into the loft I find I need to convert from cold loft to warm loft to limit excessive gas bills in the winter from the frost thermostat being constantly on. The question is - what would be the best way to achieve this? The house is a 1950's semi with no sarking under the tiles (tiles visible from inside loft). Present insulation is 200mm glass fibre on loft floor. Most loft insulation manufacturer websites I have visited assume sarking is present. Thanks in advance for any advice. -- Big G |
#2
Posted to uk.d-i-y
|
|||
|
|||
Roof pitch insulation
On Tue, 4 Jul 2006 22:07:47 +0100, Big G
wrote: Since locating our new central heating boiler into the loft I find I need to convert from cold loft to warm loft to limit excessive gas bills in the winter from the frost thermostat being constantly on. The question is - what would be the best way to achieve this? The house is a 1950's semi with no sarking under the tiles (tiles visible from inside loft). Present insulation is 200mm glass fibre on loft floor. Most loft insulation manufacturer websites I have visited assume sarking is present. Thanks in advance for any advice. How often does your loft freeze in winter? Even if it did occassionaly freeze the boiler wouldnt be using much gas as its not heating the house. I wouldnt bother. |
#3
Posted to uk.d-i-y
|
|||
|
|||
Roof pitch insulation
Most loft insulation manufacturer websites I have visited assume
sarking is present. Lack of sarking makes it easier. Think of it as a VERY breathable membrane. You can fully fill between the rafters with K7 Kingspan and then lay K18 boards underneath, tightly butted. http://www.insulation.kingspan.com/newdiv/pdf/k7.pdf Your will be the first method described in Figure 1a "Unventilated Insulation Between & Under Rafters). If you have 75mm rafters, this will give you a u-Value of 0.24. If you have 100mm rafters, this will give you a u-Value of 0.20. If using this method on an unsarked roof, you should note that you are effectively using the foil facing as an imperfect retrofit sarking. Take care at the bottom of the boards to ensure that any water moving down the surface will go outside, rather than through the bedroom ceiling. Christian. |
#4
Posted to uk.d-i-y
|
|||
|
|||
Roof pitch insulation
Big G wrote:
Since locating our new central heating boiler into the loft I find I need to convert from cold loft to warm loft to limit excessive gas bills in the winter from the frost thermostat being constantly on. The question is - what would be the best way to achieve this? Build a frame round the boiler and insulate that, sod the rest of the loft! ;-) -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Cavity wall insulation - and now the roof . .. | UK diy | |||
Low Pitch Roof and Gutters | Home Repair | |||
Limited Attic Space, no insulation, need help fast | Home Repair | |||
Limited Attic Space, no insulation, need help fast | Home Ownership | |||
Pitch and gravel roof? | Home Repair |