Default CH pump leak

I have a leak in a central heating pump.
There appear to be 2 pumps in line. Both are SMC, one (the one that is
not leaking) is a SMC Comet 2 controller. I cannot tell what the other
one is but it is an SMC but a different shape. They are 15 years+ old.
The leaking pump has a cylindrical part with 3 large phillips screws in
it. It also has 4 small holes in it. I don't know why they are there
but water was dripping out of the bottom two, so something must have
given up the ghost in the pump I presume.
In true DIY fashion, I blocked the holes as a tempory measure, but
water then started to come out of a couple of other places.
If anyone knows if this is a small straightfoward job to fix myself
then that will be good. Alternatively, any contrary advice along the
lines of "don't be silly/tight - get a plumber and new pump now", then
that will also be heeded.
Thanks in anticipation (but the carpet can't take much more water!)
Keith.

  #2   Report Post  
Posted to uk.d-i-y
Ed Sirett
 
Posts: n/a
Default CH pump leak

On Wed, 07 Jun 2006 17:17:18 -0700, keithwheeler wrote:

I have a leak in a central heating pump.
There appear to be 2 pumps in line. Both are SMC, one (the one that is
not leaking) is a SMC Comet 2 controller. I cannot tell what the other
one is but it is an SMC but a different shape. They are 15 years+ old.
The leaking pump has a cylindrical part with 3 large phillips screws in
it. It also has 4 small holes in it. I don't know why they are there
but water was dripping out of the bottom two, so something must have
given up the ghost in the pump I presume.
In true DIY fashion, I blocked the holes as a tempory measure, but
water then started to come out of a couple of other places.
If anyone knows if this is a small straightfoward job to fix myself
then that will be good. Alternatively, any contrary advice along the
lines of "don't be silly/tight - get a plumber and new pump now", then
that will also be heeded.
Thanks in anticipation (but the carpet can't take much more water!)
Keith.


Any chance of a picture of this second 'pump'?


--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards

  #3   Report Post  
Posted to uk.d-i-y
keithwheeler
 
Posts: n/a
Default CH pump leak

Ed,
Thanks for asking but I was overtaken by events (and water), couldn't
get hold a plumber in time so did the job myself. Consequently it took
about 8 hrs (4 to get 1 nut off, 2 just staring at it!) but I got there
in the end. It was basically a second pump to increase circulation (I
believe 2 pumps are no longer used) and I replaced it with a pump from
'Circulating Pumps' for £43. The casing would not come off so I never
did find out the original cause.
Thanks anyway. Keith.

Ed Sirett wrote:
On Wed, 07 Jun 2006 17:17:18 -0700, keithwheeler wrote:

I have a leak in a central heating pump.
There appear to be 2 pumps in line. Both are SMC, one (the one that is
not leaking) is a SMC Comet 2 controller. I cannot tell what the other
one is but it is an SMC but a different shape. They are 15 years+ old.
The leaking pump has a cylindrical part with 3 large phillips screws in
it. It also has 4 small holes in it. I don't know why they are there
but water was dripping out of the bottom two, so something must have
given up the ghost in the pump I presume.
In true DIY fashion, I blocked the holes as a tempory measure, but
water then started to come out of a couple of other places.
If anyone knows if this is a small straightfoward job to fix myself
then that will be good. Alternatively, any contrary advice along the
lines of "don't be silly/tight - get a plumber and new pump now", then
that will also be heeded.
Thanks in anticipation (but the carpet can't take much more water!)
Keith.


Any chance of a picture of this second 'pump'?


--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Goulds Irrigation pump Not Working HELP [email protected] Home Repair 1 May 31st 06 09:47 PM
Leak burnt water pump, didn't trip any fuses but shocked me! cs UK diy 2 July 18th 05 07:11 PM
OT-Shriners Raffle. Of interest Gunner Metalworking 0 April 10th 05 08:33 AM
Well Pump Difficult Starting--Question About Wire Color Codes Mark & Mary Ann Weiss Home Repair 11 April 9th 05 02:31 AM
Backup Sump Pump Horror Story Harvey Krodin Home Repair 10 June 27th 03 02:59 PM


All times are GMT +1. The time now is 06:28 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"