UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to uk.d-i-y
thankyousam
 
Posts: n/a
Default Running lighting cable over/through joists in loft.

The joists in my loft are less than 100mm in height, meaning that it is
impossible to drill a hole that is 50mm from both the top /and/ bottom
of the joist. I've found other posts that say to run the cable over
the top of the joist and have a baton either side and place steel
strips over the top, e.g.
http://groups.google.co.uk/group/uk....6345a2c9687a7d

In parts the cable/joists will have boards over the top. Can the cable
be run without earthed trunking/conduit? and does this comply with the
building regs? I can't find anything which explicity covers this in
the On Site Guide or the BS7671 Blue Book.

  #2   Report Post  
Posted to uk.d-i-y
Lightman
 
Posts: n/a
Default Running lighting cable over/through joists in loft.

Why not drill through the joists 50mm from the bottom and put 3mm steel
plates over the top to protect from screws.

I beleive this is allowed in the on site guide

Regards - Lightingman

  #3   Report Post  
Posted to uk.d-i-y
thankyousam
 
Posts: n/a
Default Running lighting cable over/through joists in loft.

As a slight aside, given the height of the joists will I be able to run
the cables along the length/side of the joists, holding them in place
with cable clips?

  #4   Report Post  
Posted to uk.d-i-y
John McLean
 
Posts: n/a
Default Running lighting cable over/through joists in loft.


"thankyousam" wrote in message
oups.com...
As a slight aside, given the height of the joists will I be able to run
the cables along the length/side of the joists, holding them in place
with cable clips?


This is acceptable, and is the standard way of installing Twin & Earth, PVCI
cables running the length of the joists. If there is thermal insulation laid
"between the joists", the cable should be run preferably, at a height
corresponding to the upper surface of the insulation layer, to avoid
unnecessary cable derating; but in any case, at a height of at least 50mm to
the underside of the cable, measured from the bottom of the joist. (This is
to avoid possible nail damage from below the ceiling).


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Raising Roof Joists for Loft Flooring Dave Page UK diy 34 March 23rd 06 10:58 PM
Lighting in loft conversion Adam-the-Kiwi UK diy 16 November 28th 05 11:30 AM
Adding CH to new loft - advice please [email protected] UK diy 19 January 7th 04 08:58 AM
using 30A cable to supply 5A lighting circuit: good idea? dave L UK diy 3 October 7th 03 10:08 PM
Routeing Electrical FTE cable pickerel UK diy 3 July 24th 03 12:43 AM


All times are GMT +1. The time now is 08:37 PM.