I have Just purchased a "Combination Direct Hot Water Cylinder " ( Not
Combi Boiler !) ...

I am not a plumber but think I can manage to connect a few pipes
myself... !

However I am baffled what all the 22mm holes are for and to which one
Is the actual Draw off one , Can any one tell me ?

On the one side top & bottom of the cylinder ,it has 2 x 22mm holes
adjacent,
On other side side top 22mm hole and bottom 15mm hole (Drain off point
)

Which of the other 3 option 22mm holes is the draw off point?? and
what are the other 2 for anyway ??

Also no hole for Ball valve in header tank Section of this Combi
Cylinder How far from the top should one drill the hole for the Ball
valve Fitting ?

Any help Appreciated

Thanks

  #2   Report Post  
Posted to uk.d-i-y
Andy Hall
 
Posts: n/a
Default Installing a New direct Combination Hot Water Cylinder

On 25 Feb 2006 22:41:07 -0800, "Midboy" wrote:

I have Just purchased a "Combination Direct Hot Water Cylinder " ( Not
Combi Boiler !) ...


Can you supply make and model?

I am not a plumber but think I can manage to connect a few pipes
myself... !

However I am baffled what all the 22mm holes are for and to which one
Is the actual Draw off one , Can any one tell me ?

On the one side top & bottom of the cylinder ,it has 2 x 22mm holes
adjacent,


This suggests that it has a coil for connecting to a CH system. Try
pouring some water into the top one through a tube and see if it comes
out of the bottom one without going into the cylinder.



On other side side top 22mm hole and bottom 15mm hole (Drain off point
)


The top one should be the draw off. Put water into that and see if it
comes out of the 15mm one at the bottom. The smaller one should be
the drain as you say.



Which of the other 3 option 22mm holes is the draw off point?? and
what are the other 2 for anyway ??

Also no hole for Ball valve in header tank Section of this Combi
Cylinder How far from the top should one drill the hole for the Ball
valve Fitting ?


That's surprising. Typically about 75mm down from the top, possibly
slightly less. Don't forget the overflow.....



Any help Appreciated

Thanks


--

..andy

  #3   Report Post  
Posted to uk.d-i-y
Midboy
 
Posts: n/a
Default Installing a New direct Combination Hot Water Cylinder

Thanks Andy
I Don`t think it has a coil circuit (IE going into a inner pipe) its
just vacant open space into the tank space ,as with all the holes
.....Just two 22mm Ports Standard on oneside Top and bottom..(I assume
I have to blank them off ,maybe manufactered to a standard pattern
but without the coil with the Direct, and perhaps with,coil in the
case of the indirect ..)
One hole on opposite side Top 22MM (maybe this is the draw off point
?)
and ....Bottom 15mm obviously for Drain off Plug/tap
See this link for drawing copy and paste
http://www.heatandplumb.co.uk/acatal... linders.html

It it an Albion direct combination hot water cylinder with integral
header tank the expansion pipe is built in and feed into tank .....but
no hole for ball valve or overflow , I think you have to cut them
yourself to suit positioning I guess ?
Thanks

Midboy Keith @

  #4   Report Post  
Posted to uk.d-i-y
Andy Hall
 
Posts: n/a
Default Installing a New direct Combination Hot Water Cylinder

On 26 Feb 2006 05:16:57 -0800, "Midboy" wrote:

Thanks Andy
I Don`t think it has a coil circuit (IE going into a inner pipe) its
just vacant open space into the tank space ,as with all the holes
....Just two 22mm Ports Standard on oneside Top and bottom..(I assume
I have to blank them off ,maybe manufactered to a standard pattern
but without the coil with the Direct, and perhaps with,coil in the
case of the indirect ..)


There's a better picture at

http://rangecylinders.co.uk/products...tf1/index.html

A direct cylinder usually means one designed to go with a hot water
only type of boiler like a wood stove, coal back boiler that doesn't
do heating or similar. The two 22mm taps would be to connect it to
said boiler and have the water circulate by convection (aka gravity)
through the boiler.

An indirect cylinder has a coil inside between the same two tappings.


You're right. You can blank them off. The HW take off is the one at
the top on the left.



One hole on opposite side Top 22MM (maybe this is the draw off point
?)
and ....Bottom 15mm obviously for Drain off Plug/tap
See this link for drawing copy and paste
http://www.heatandplumb.co.uk/acatal... linders.html

It it an Albion direct combination hot water cylinder with integral
header tank the expansion pipe is built in and feed into tank .....but
no hole for ball valve or overflow , I think you have to cut them
yourself to suit positioning I guess ?


It rather looks that way....

I suppose it has the advantage that you can put them where you like.



Thanks

Midboy Keith @


--

..andy

  #5   Report Post  
Posted to uk.d-i-y
Midboy
 
Posts: n/a
Default Installing a New direct Combination Hot Water Cylinder

Thanks Andy for the Link and your Info , I am now satified that it is
the Top Left 22mm hole is the draw off point as you say !
Cheers, Much Appreciated ...
Keith

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
AquaTherm Furnace - No Hot Water Issue David Home Repair 11 January 25th 18 08:44 PM
Salt content of softened water Steve B Home Repair 26 January 25th 06 04:06 AM
Detergents and cleaners FAQ [email protected] UK diy 49 September 25th 05 11:34 PM
Heat banks (again!) Dave UK diy 148 September 6th 04 08:45 PM
hot water recirculator, instant hot water but not a water heating unit, saves water, gas, time, money HeatMan Home Repair 0 August 24th 03 12:26 PM


All times are GMT +1. The time now is 03:20 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"