UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to uk.d-i-y
 
Posts: n/a
Default dormer loft conversion structural ?

Can someone describe the usual structural work required for a dormer
conversion from
a traditional rafter/purlin roof, i.e. the usual way of supporting the
ridge / dormer roof etc.
Thanks,
Simon.

  #2   Report Post  
Posted to uk.d-i-y
 
Posts: n/a
Default dormer loft conversion structural ?

Can someone describe the usual structural work required for a dormer
conversion from
a traditional rafter/purlin roof, i.e. the usual way of supporting the
ridge / dormer roof etc.
Thanks,
Simon.


Simon,
I have just built a Dormer myself. Basically the two vertical
side walls were built using 4" x 2" studs at 400mm. spacing. These
walls were held apart by 4" x 2" at 400mm spacing at a height of 2
metres. The ridge of the dormer can either 'T' into the existing main
ridge or be set down by say one foot. The angle formed by the new
ceiling 4" x 2"s and the new ridge timber should be about 35 degrees.
This angle is quite variable and can be set just so that the dormer
looks right. As mine will be finished using slates, the outside of the
4 x 2 walls were covered in 22mm x 150mm 'sarking' boards. The whatever
roofing felt ontop of that. Wait until the Spring.

I can send some digi photos if you send your e-mail to...


Chris.

  #3   Report Post  
Posted to uk.d-i-y
 
Posts: n/a
Default dormer loft conversion structural ?

I have just built a Dormer myself. Basically the two vertical
side walls were built using 4" x 2" studs at 400mm. spacing. These
walls were held apart by 4" x 2" at 400mm spacing at a height of 2
metres. The ridge of the dormer can either 'T' into the existing main
ridge or be set down by say one foot. The angle formed by the new
ceiling 4" x 2"s and the new ridge timber should be about 35 degrees.
This angle is quite variable and can be set just so that the dormer
looks right. As mine will be finished using slates, the outside of the
4 x 2 walls were covered in 22mm x 150mm 'sarking' boards. The whatever
roofing felt ontop of that. Wait until the Spring.

What about support of the house roof ridge, now that rafters and
purlins are
removed ? RSJs ?
35 degrees - are you saying your dormer does not have a flat roof ?

Cheers,
Simon.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
A not-quite loft conversion Chris Styles UK diy 5 October 5th 05 08:30 AM
Loft conversion - technical questions hansen UK diy 11 April 19th 05 07:51 PM
Loft insulation question with a view to future conversion.... Simon Hawthorne UK diy 9 November 13th 04 11:48 PM
loft conversion, low roof, detached house dundonald UK diy 4 October 7th 04 01:20 PM
hip roof loft conversion Chris Allmark UK diy 15 March 2nd 04 06:09 PM


All times are GMT +1. The time now is 10:16 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"