As you may have seen in other posts I am adding a spur socket to one of my
existing ones.

I have one more question.

Is there a minimum depth that the cable needs to be traced into the wall?

TIA

--
Steve




  #2   Report Post  
Posted to free.uk.diy.home,uk.d-i-y
Nigel Molesworth
 
Posts: n/a
Default Mains cable

On Mon, 21 Nov 2005 10:48:49 -0000, Steve Rainbird wrote:

Is there a minimum depth that the cable needs to be traced into the wall?


Providing it goes vertically from the socket, no.

--
Nigel M
  #3   Report Post  
Posted to free.uk.diy.home,uk.d-i-y
Christian McArdle
 
Posts: n/a
Default Mains cable

Is there a minimum depth that the cable needs to be traced into the wall?

Either 50mm, or not at all.

Not at all only applies if the run is in a specially prescribed zone, which
includes at the end of a wall, at the top of a wall (not bottom), or
vertically from a visible electrical fitting. You can also run horizontally
from one, but this is usually discouraged.

If you install at any other location, you need 50mm depth or mechanical
protection.

Christian.


  #4   Report Post  
Posted to free.uk.diy.home,uk.d-i-y
Paul Saunders
 
Posts: n/a
Default Mains cable

If you look more closely at the regs this rule only applies if the cable is
concealed in the wall and not being terminated in an outlet. ie. if there is
no way of knowing that the cable is there. With an outlet present you know
there is a cable running vertically or horizontally.(Or, you should be able
to assume so). Again, if it runs diagonally it has to be 50mm or
mechanically protected.


"Steve Rainbird" wrote in message
...
As you may have seen in other posts I am adding a spur socket to one of my
existing ones.

I have one more question.

Is there a minimum depth that the cable needs to be traced into the wall?

TIA

--
Steve






Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Jointing mains cable with crimps Andy Luckman (AJL Electronics) UK diy 71 June 24th 05 06:14 PM
Mains cable behind wall antgel UK diy 7 May 22nd 05 08:03 PM
Garden cabling / electricity - part two! Dundonald UK diy 1 March 26th 05 12:52 AM
Further Earth Bonding questions [email protected] UK diy 34 September 15th 04 08:49 AM
Drilling through mains cable! N UK diy 27 January 14th 04 01:37 AM


All times are GMT +1. The time now is 10:24 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"