UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

 
 
LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #1   Report Post  
TheScullster
 
Posts: n/a
Default Central Heating - Expert Assistance Required

Hi all

I am trying to improve the operation of my central heating system and would
appreciate the opinions of the more experienced group members.

The story is:

Originally 3 bed detached 1970s house.

Additions since built:

1 Kitchen extension with 1 rad single panel rad 1200 x 600
1 Back room extension with 1 double panel rad 1000 x 600
1 Bedroom/En suite with rad and towel rail (see link)

http://www.thesculls.freeuk.com/Radpipes.jpg

Referring to image (which shows upstairs piping and radiators only), the
problem is little heat to new bedroom rad 7 and almost nothing to towel rail
6.
Downstairs main runs are 22mm, but upstairs is all 15mm.
Not sure if it is significant, but the new part that hardly works is piped
in plastic - see link for plastic/copper joint location.

Another factor that may affect the towel rail operation is the height.
Somewhere I seem to remember reading that a certain distance was required
between the top of a towel rail and the underside of the loft CH header
tank. In my case this distance is approx 650mm.

I have tried major throttling of the downstairs rads to improve flow
upstairs, but do not seem to be able to get acceptable performance of
upstairs and downstairs rads to include items 6 and 7.

So the question:

Looking at the pipe runs and radiator sizes involved upstairs, are 15mm
mains simply not up to the job?

Thanks to anyone who has even managed to read this far!

Phil


 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Rayburn integrated into central heating David Cawkwell UK diy 2 February 8th 05 06:23 PM
Central heating advice Wordy UK diy 4 January 7th 05 08:19 AM
Central Heating control unit replacement - advice please Damian Home Repair 1 December 29th 03 01:35 AM
Central Heating costs + other questions The Question Asker UK diy 7 December 1st 03 06:28 PM
No central heating - HW only threewayvalve and tank therm John UK diy 7 September 29th 03 09:18 AM


All times are GMT +1. The time now is 06:50 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"