  #1   Report Post  
Junior Member
 
Posts: 14
Default Replacing radiator with Towel Heater

I've just purchased a towel rail radiator to replace an old bathroom radiator. The problem i have is the towel radiator is only 35cm wide whereas the old radiator was 45cm. Also the valves screw in vertically (from the bottom) and the current valves screw in horizontally. The pipes to all the radiators in the house are 10mm and are behind the wall (plasterboard) rather than under the floor boards.

Is there an easy way (suitable for a novice plumber) to replace the valves and reduce the width between the valves from 45cm to 35cm without draining and disabling the central heating tank in the loft? Or could someone point me in the right direction to an idiots guide on this?
  #2   Report Post  
al
 
Posts: n/a
Default

"preecy" wrote in message
news
Is there an easy way (suitable for a novice plumber) to replace the
valves and reduce the width between the valves from 45cm to 35cm
without draining and disabling the central heating tank in the loft? Or
could someone point me in the right direction to an idiots guide on
this?


You can buy extender valves in Wickes, etc. that will let you add about 5cm
per side if you want.



a


  #3   Report Post  
Alan
 
Posts: n/a
Default


"preecy" wrote in message
news

I've just purchased a towel rail radiator to replace an old bathroom
radiator. The problem i have is the towel radiator is only 35cm wide
whereas the old radiator was 45cm. Also the valves screw in vertically
(from the bottom) and the current valves screw in horizontally. The
pipes to all the radiators in the house are 10mm and are behind the
wall (plasterboard) rather than under the floor boards.

Is there an easy way (suitable for a novice plumber) to replace the
valves and reduce the width between the valves from 45cm to 35cm
without draining and disabling the central heating tank in the loft? Or
could someone point me in the right direction to an idiots guide on
this?


--
preecy


No, you will have to drain the system, and use some elbows to bring the
current pipework to the new rad, then re-fill system (and remember
inhibitor).

Alan.


  #4   Report Post  
Wingedcat
 
Posts: n/a
Default


I've just purchased a towel rail radiator to replace an old bathroom
radiator. The problem i have is the towel radiator is only 35cm wide
whereas the old radiator was 45cm. Also the valves screw in vertically
(from the bottom) and the current valves screw in horizontally. The
pipes to all the radiators in the house are 10mm and are behind the
wall (plasterboard) rather than under the floor boards.

Is there an easy way (suitable for a novice plumber) to replace the
valves and reduce the width between the valves from 45cm to 35cm
without draining and disabling the central heating tank in the loft? Or
could someone point me in the right direction to an idiots guide on
this?


There is no idiot's guide, you will have to do the job properly man.
This means a complete drain down and a modification to the existing
pipework.

If I were you I would mount the new radiator so that one of the CH
pipes (which I assume comes up from the floor) feeds directly into one
of the new vertical valves. This will mean discarding the existing 90
degree valve and probably cutting off a few mm of pipe in order to
accept the new olive.

Then you will have to fashion an "S" shape out of copper pipe (two 90
degree elbows and a couple of small lengths) to allow the other CH pipe
to connect to the other valve, obviously discarding the other existing
horizontal valve.

You will need a length of (probably 15mm) copper tubing, a blowlamp,
flux, wire wool, solder, elbows, and a pipe cutter.

After the job is done you will have to rebalance the system for the new
rad (see FAQ).

Note that the wall fixings for these towel radiators require very
precise positioning of the pipes! (No margin for error!)

Luke

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
AquaTherm Furnace - No Hot Water Issue David Home Repair 11 January 25th 18 08:44 PM
Replacing a termal fuse in a night storage heater Daniel Towner UK diy 4 March 4th 05 08:50 PM
Taking a radiator (towel heater) off help please Richard Clay UK diy 2 October 24th 04 03:21 PM
Removing a hydronic towel heater help? JMC UK diy 3 June 5th 04 01:25 AM
Removing a hydronic towel heater rail help? Bob Mannix UK diy 1 July 10th 03 03:01 PM


All times are GMT +1. The time now is 11:59 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"