Home |
Search |
Today's Posts |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
Posted to sci.electronics.repair
|
|||
|
|||
Looking for MAN-10A 7 segment LED display
One segment of the display on my early model Fluke 3000A DVM stopped
functioning yesterday, so I am looking for a replacement. Has anyone on the group got an old Monsanto MAN-10A display, the ones with the LED arrays visible, not the later ones with the 'light pipe' over the LEDs? I would be interested in one [or more] display, a Fluke 3000A display assembly or even an old, non- working Fluke 3000A for parts. Also would appreciate pointers to other groups that might be able to help. I tried Google and eBay without any luck. Neil S. |
#2
Posted to sci.electronics.repair
|
|||
|
|||
Looking for MAN-10A 7 segment LED display
On Dec 20, 10:40*pm, nesesu wrote:
One segment of the display on my early model Fluke 3000A DVM stopped functioning yesterday, so I am looking for a replacement. Has anyone on the group got an old Monsanto MAN-10A display, the ones with the LED arrays visible, not the later ones with the 'light pipe' over the LEDs? I would be interested in one [or more] display, a Fluke 3000A display assembly or even an old, non- working Fluke 3000A for parts. Also would appreciate pointers to other groups that might be able to help. I tried Google and eBay without any luck. Neil S. Oops, I should have said "Fluke 8000A" ! Neil S. |
#3
Posted to sci.electronics.repair
|
|||
|
|||
Looking for MAN-10A 7 segment LED display
On Tue, 21 Dec 2010 07:24:19 -0800 (PST) nesesu
wrote in Message id: : On Dec 20, 10:40*pm, nesesu wrote: One segment of the display on my early model Fluke 3000A DVM stopped functioning yesterday, so I am looking for a replacement. Has anyone on the group got an old Monsanto MAN-10A display, the ones with the LED arrays visible, not the later ones with the 'light pipe' over the LEDs? I would be interested in one [or more] display, a Fluke 3000A display assembly or even an old, non- working Fluke 3000A for parts. Also would appreciate pointers to other groups that might be able to help. I tried Google and eBay without any luck. Neil S. Oops, I should have said "Fluke 8000A" ! Mouser lists this as a replacement: http://www.mouser.com/ProductDetail/...2bvm gCJuE%3d |
#4
Posted to sci.electronics.repair
|
|||
|
|||
Looking for MAN-10A 7 segment LED display
On Dec 21, 10:24*am, nesesu wrote:
On Dec 20, 10:40*pm, nesesu wrote: One segment of the display on my early model Fluke 3000A DVM stopped functioning yesterday, so I am looking for a replacement. Has anyone on the group got an old Monsanto MAN-10A display, the ones with the LED arrays visible, not the later ones with the 'light pipe' over the LEDs? I would be interested in one [or more] display, a Fluke 3000A display assembly or even an old, non- working Fluke 3000A for parts. Also would appreciate pointers to other groups that might be able to help. I tried Google and eBay without any luck. Neil S. Oops, I should have said "Fluke 8000A" ! Neil S. Seems odd that the whole thing would go tits up all at once. Have you swapped one of the others into the "dead" position to verify that the driver circuitry is still functioning? I have some HP 5082-7760 numeric red LED blocks if that'll replace what you have. Datasheet: http://pdf1.alldatasheet.co.kr/datas...5082-7760.html |
#5
Posted to sci.electronics.repair
|
|||
|
|||
Looking for MAN-10A 7 segment LED display
On Dec 24, 12:34*pm, boardjunkie wrote:
On Dec 21, 10:24*am, nesesu wrote: On Dec 20, 10:40*pm, nesesu wrote: One segment of the display on my early model Fluke 3000A DVM stopped functioning yesterday, so I am looking for a replacement. Has anyone on the group got an old Monsanto MAN-10A display, the ones with the LED arrays visible, not the later ones with the 'light pipe' over the LEDs? I would be interested in one [or more] display, a Fluke 3000A display assembly or even an old, non- working Fluke 3000A for parts. Also would appreciate pointers to other groups that might be able to help. I tried Google and eBay without any luck. Neil S. Oops, I should have said "Fluke 8000A" ! Neil S. Seems odd that the whole thing would go tits up all at once. Have you swapped one of the others into the "dead" position to verify that the driver circuitry is still functioning? I have some HP 5082-7760 numeric red LED blocks if that'll replace what you have. Datasheet:http://pdf1.alldatasheet.co.kr/datas.../5082-7760...- Hide quoted text - - Show quoted text - Thanks for the offer. A friend on the internet has just found a duff 8000A and is sending it to me as a parts 'donor', so I hope it has a good display since it is of the slightly later 'light pipe' style and I would not want to mix and match the displays in one instrument unless it is unavoidable. As far as the fault on my instrument, it has a failure if the segment 'b' in the middle digit [3-1/2 digit display]. Since the low side multiplexing has 1 drive to the 'b' segments of all 4 digits in parallel and the high side multiplex drives the common anode of each digit, the problem has to be in the connection from the segment buss through the LED of the segment to the common anode buss in the one digit because all other digits and segments work correctly showing that the multiplex drivers are functioning normally. The soldering of the display to the circuit board is good, leaving the open circuit to be somewhere inside the one display package. All the best for the Christmas season to all who follow these NGs and a special thanks to all those who have given me pointers and offers of parts to fix my DVM on and off line! All the best! Neil S. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
7 segment display with 4 digits | Electronics Repair | |||
looking to build or find inexpensive 3-digit 7-segment LED display | Electronics Repair | |||
Digital 7 Segment Display | Electronics | |||
Odd 7-segment display | Electronics Repair | |||
what is the best way to go about fixing a bad LCD led segment | Electronics Repair |