Home |
Search |
Today's Posts |
|
Metalworking (rec.crafts.metalworking) Discuss various aspects of working with metal, such as machining, welding, metal joining, screwing, casting, hardening/tempering, blacksmithing/forging, spinning and hammer work, sheet metal work. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
|
|||
|
|||
monarch 10ee electrical
i just bought a 10ee monarch 1980b-day it says it is for 460 volts, can this
be rewired to operate on 220 3phase, or do i need a stepup transformer and what rating |
#2
|
|||
|
|||
monarch 10ee electrical
I have a 1966 10ee that is set up for 460 volts. Prior to its
delivery I contacted Monarch to see what needed changing to get down to 230. The helpful tech send me a fax copy of the schematic and indicated where changes needed to be made. He said that the two filament transformers might need to be replaced, and they were a couple hundred dollars each. Not to mention, there are two shunts that need to be custom made for the lower voltage. After I looked at the job and the cost, I got cold feet. Long story short I bought a nice new 7.5kv step-up transformer (about $250) and run the machine on the 460v for which it is configured. Runs real nice. You might be able to find one cheaper, but I didn't want to play russian roulette with this one. Neil P.S. Either way, if you care, you'll need to resolve how to run the 3-phase coolant pump. A small VFD or static convertor would do fine. I haven't run mine yet... On 27 Mar 2004 00:00:32 GMT, (Asp3211968) wrote: i just bought a 10ee monarch 1980b-day it says it is for 460 volts, can this be rewired to operate on 220 3phase, or do i need a stepup transformer and what rating |
#3
|
|||
|
|||
monarch 10ee electrical
For most 10EEs, the best course is a 240:480 transformer. There is more to it than the two filament transformers (Modular) or the filament transformer and field anode transformer (WiaD). The C-H contactor, the pilot light transformer and the work light transformer, for example. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Earth Bondng | UK diy | |||
Electrical wiring inspector? | UK diy |