plastic junction box w/ pbx wires not grounded
I have an older home with a mix between romex and pbx wiring. I was
testing the outlets and found that there are 2 that are not grounded, which are fed with pbx. I found the junction box in the light fixture that they are connected to was replaced w/ a blue plastic box and there is nothing that grounds the 4 pbx wires going into it together (source feed, switch & 2 outlets) My question is, should I attempt to solder a common ground wire between each pbx wire, or replace the junction box? I'd rather not replace the box, but I will if there are no other alternatives. Are those plastic boxes made to support pbx wiring? |
#2
|
|||
|
|||
On 19 Jan 2005 05:30:19 -0800, "
wrote: I have an older home with a mix between romex and pbx wiring. I was testing the outlets and found that there are 2 that are not grounded, which are fed with pbx. I found the junction box in the light fixture that they are connected to was replaced w/ a blue plastic box and there is nothing that grounds the 4 pbx wires going into it together (source feed, switch & 2 outlets) My question is, should I attempt to solder a common ground wire between each pbx wire, or replace the junction box? I'd rather not replace the box, but I will if there are no other alternatives. Are those plastic boxes made to support pbx wiring? IMHO: Replace the box. I don't believe the code will allow for a grounding path to be made up of soldered links. later, tom @ www.URLBee.com |
#3
|
|||
|
|||
|
#4
|
|||
|
|||
Thanks for the info. It looks as if the pbx cables are not secured to
the box at all ( i was able to pull some slack on one of them) So if I were not to replace the box, I would have to clap a connector to each cable and run a ground wire to each of them? Thanks again -Owen |
#6
|
|||
|
|||
On Thu, 20 Jan 2005 12:06:29 -0600, wrote:
On Thu, 20 Jan 2005 08:31:17 -0500, wrote: On Wed, 19 Jan 2005 20:48:53 -0600, wrote: On 19 Jan 2005 05:30:19 -0800, " wrote: I have an older home with a mix between romex and pbx wiring. I was testing the outlets and found that there are 2 that are not grounded, which are fed with pbx. I found the junction box in the light fixture that they are connected to was replaced w/ a blue plastic box and there is nothing that grounds the 4 pbx wires going into it together (source feed, switch & 2 outlets) My question is, should I attempt to solder a common ground wire between each pbx wire, or replace the junction box? I'd rather not replace the box, but I will if there are no other alternatives. Are those plastic boxes made to support pbx wiring? I hate those plastic boxes. Mostly because there is no way to ground them. On the metal boxes there is a hole on the rear for a green screw. They never put the holes on these plastic boxes, so I am stuck with ungrounded boxes, I do not like that at all. Curious, why the big concern about wanting to ground your boxes? later, tom @ www.URLBee.com Electrical boxes have been grounded ever since safe grounding methods went into use. Just when we finally had very safe electrical systems, if the codes are followed, we are now going backwards. The purpose of grounding electrical boxes is to protect the user from electricution. Now, with these ungrounded plastic boxes, the user is once again in danger of electricution from touching the box. Granted, the ground terminal (green screw) on the outlet is connected to ground, but not the box itself. I personally refuse to use these plastic boxes. Not only are they dangerous to people, but are also a fire hazzard, since they burn if an outlet fire starts, and actually add to the fire.. A metal box provides some means to stop a fire before the fire gets to flammable materials, and surely does not ADD to the fire. I understand your choice in metal boxes over plastic is based on your experience and option; so, nothing wrong there, but I too was skittish about plastic boxes till I found they are rated for 2 hours, which gives time for your evacuation, and extinghishing of it. So, to weight, I use plastic when I can. later, tom @ www.ChopURL.com |
#7
|
|||
|
|||
grounding electrical boxes is to protect the user from electricution. Now, with these ungrounded plastic boxes, the user is once again in danger of electricution from touching the box. Granted, the ground It's REALLY hard to electrocute yourself by touching a plastic box. Not quite impossible, but tough. I'd say that a grounded metal box is probably more dangerous, as it provides electricity from other sources with someplace to go. |
#8
|
|||
|
|||
|
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Wires contacts with plastic sheets/insulations, bad? | Home Repair | |||
Earth Bondng | UK diy | |||
Joining Plastic Waste pipe to Lead pipe | UK diy | |||
Radio Signal tool for tracing wires | Home Repair | |||
wiring a three phase motor | Metalworking |