I live in a house built in '65 timeframe. I've been in it approx 7 yrs now.

In the master bedroom, there is a large, ornate ceiling fan. It 's a very
typical type --- several lights under the blades. There are pull chains
which give me 3 fan speeds and several light levels.

The wall power controller is unusual, and I don't know what the heck it is,
or why they didn't put in a conventional switch. But, what's there in a
standard wall outlet box, is some kind of gizmo that has a horizontal rocker
switch on top, a horizontal slider switch in the middle, and a horizontal
rocker switch on the bottom. I have no idea how it's supposed to work. I
just fiddle with it until the fan and/or lights come on.

Anyway, where this discussion is going, is that the other day the fan was
running on high, and I just happened to notice that the faceplate on the
wall power control was very hot. Obviously, this isn't good.

The question I've got is: is there any reason why I shouldn't pull thegizmo
that's there, and replace it with a conventional toggle switch???


  #2   Report Post  
Art
 
Posts: n/a
Default

How hot is very hot. Fan controls often get warm to the touch.


"RB" wrote in message
. ..
I live in a house built in '65 timeframe. I've been in it approx 7 yrs

now.

In the master bedroom, there is a large, ornate ceiling fan. It 's a very
typical type --- several lights under the blades. There are pull chains
which give me 3 fan speeds and several light levels.

The wall power controller is unusual, and I don't know what the heck it

is,
or why they didn't put in a conventional switch. But, what's there in a
standard wall outlet box, is some kind of gizmo that has a horizontal

rocker
switch on top, a horizontal slider switch in the middle, and a horizontal
rocker switch on the bottom. I have no idea how it's supposed to work. I
just fiddle with it until the fan and/or lights come on.

Anyway, where this discussion is going, is that the other day the fan was
running on high, and I just happened to notice that the faceplate on the
wall power control was very hot. Obviously, this isn't good.

The question I've got is: is there any reason why I shouldn't pull

thegizmo
that's there, and replace it with a conventional toggle switch???




  #3   Report Post  
RB
 
Posts: n/a
Default

Well, not hot enough to burn, unless you left your hand flat on it for
awhile. Definitely uncomfortable, though.


  #4   Report Post  
Joe Bobst
 
Posts: n/a
Default

The question I've got is: is there any reason why I shouldn't pull thegizmo
that's there, and replace it with a conventional toggle switch???

Since the switch and fan assembly were designed to work together it would be
prudent to keep things original or else replace both fan and controls with
modern units. Might be the heat you're sensing is from an early type of SCR
dimmer or speed control in the center section. Whatever, proceed carefully and
use well rated components. Good luck.

Joe

  #5   Report Post  
Curmudgeon
 
Posts: n/a
Default

For 7 years you haven't cared....why start now? Just "fiddle with it"
until it gets cool.


"RB" wrote in message
. ..
I live in a house built in '65 timeframe. I've been in it approx 7 yrs

now.

In the master bedroom, there is a large, ornate ceiling fan. It 's a very
typical type --- several lights under the blades. There are pull chains
which give me 3 fan speeds and several light levels.

The wall power controller is unusual, and I don't know what the heck it

is,
or why they didn't put in a conventional switch. But, what's there in a
standard wall outlet box, is some kind of gizmo that has a horizontal

rocker
switch on top, a horizontal slider switch in the middle, and a horizontal
rocker switch on the bottom. I have no idea how it's supposed to work. I
just fiddle with it until the fan and/or lights come on.

Anyway, where this discussion is going, is that the other day the fan was
running on high, and I just happened to notice that the faceplate on the
wall power control was very hot. Obviously, this isn't good.

The question I've got is: is there any reason why I shouldn't pull

thegizmo
that's there, and replace it with a conventional toggle switch???






  #6   Report Post  
RB
 
Posts: n/a
Default

Never had occasion to feel it after it's been on awhile, before this.
Normally we turn it off with the pull chain. This just happened to be the
first time I've turned it off at the wall prior to a cool down period for
the control.

The question is/was: can I put a conventional switch in place of the
controller. Seems the answer is no.

So, the answer is a new fan and control.


  #7   Report Post  
KJS
 
Posts: n/a
Default

On Sun, 29 Aug 2004 11:41:21 -0700, RB wrote
(in article ):

I live in a house built in '65 timeframe. I've been in it approx 7 yrs now.

In the master bedroom, there is a large, ornate ceiling fan. It 's a very
typical type --- several lights under the blades. There are pull chains
which give me 3 fan speeds and several light levels.

The wall power controller is unusual, and I don't know what the heck it is,
or why they didn't put in a conventional switch. But, what's there in a
standard wall outlet box, is some kind of gizmo that has a horizontal rocker
switch on top, a horizontal slider switch in the middle, and a horizontal
rocker switch on the bottom. I have no idea how it's supposed to work. I
just fiddle with it until the fan and/or lights come on.

Anyway, where this discussion is going, is that the other day the fan was
running on high, and I just happened to notice that the faceplate on the
wall power control was very hot. Obviously, this isn't good.

The question I've got is: is there any reason why I shouldn't pull thegizmo
that's there, and replace it with a conventional toggle switch???


RB -

Ceiling fans typically use capacative speed controls. If there is a
pull-chain on the fan for speed control, then there shouldn't be a speed
control in the wall switch assembly as well. The instructions with a ceiling
fan that has an internal speed control warn against this as a fire hazard.
(Unless the fan is made to take an external speed control, in which case
there's a way of removing or permanently bypassing the internal one.)

From your description, it's likely that someone installed a speed control in
the wall switchbox with the intention that the control on the fan would
always be left on high (no capacitors in the circuit) and the wall control
would be used instead. The problem is that using two speed controls in
series can result in overheating of one or both sets of capacitors.

I think you would be wise to replace the wall control.

Have you opened up the wall box to see how the device is wired? There are
possibly two switched wires and a neutral running from the device to the fan.
One would control the lights, the other one the fan motor. If that is the
case, you should replace the wall speed control with a pair of switches.
Alternatively, you may put a dimmer on the light circuit, but NOT on the fan
motor circuit.

If there is only one switched wire and a neutral going to the fan, then just
replace the controller with a regular switch.

Good luck.

- Kenneth

  #8   Report Post  
barry martin
 
Posts: n/a
Default

RB:

R Never had occasion to feel it after it's been on awhile, before this.
R Normally we turn it off with the pull chain. This just happened to be the
R first time I've turned it off at the wall prior to a cool down period for
R the control.
R
R The question is/was: can I put a conventional switch in place of the
R controller. Seems the answer is no.
R
R So, the answer is a new fan and control.

From here I'd say you would be able to replace the controller with a
conventional switch. The controller is nothing but a fancy switch. A
switch does nothing more than on and off; the controller also does on
and off plus varies the degree of 'on'.

Personally I'd go with two switches: one for the light and one for the
fan. They are available in a duplex outlet configuration.
....Actually I'd go with the a new controller should that be the
problem.

-
¯ barry.martinþATþthesafebbs.zeppole.com ®

* Why does a Mummy make a bad birthday gift? Because too hard to unwrap!
---
þ RoseReader 2.52á P003186
þ The Safe BBS þ Bettendorf, IA 563-359-1971
---
þ RIMEGate(tm)/RGXMod V1.13 at BBSWORLD *
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
celing isue Stephanie Stowe Home Repair 7 April 21st 04 06:10 PM
Central Heating control unit replacement - advice please Damian Home Repair 1 December 29th 03 01:35 AM
Installing Ceiling Fan with Red wire on electrical box. Josh Home Repair 20 July 31st 03 11:53 AM


All times are GMT +1. The time now is 07:25 AM.