Cost of freon 22
"Stormin Mormon" wrote in message ... Lot of factors go on, here. Of course, retail is higher than wholesale. Now that R22 isn't made any more, it's going to go up in price. Also, that markup helps pay taxes, wages, taxes, equipment costs, taxes, advertising, taxes, and of course, taxes. Sounds about right, to me. Cut and pasted : The Clean Air Act does not allow any refrigerant to be vented into the atmosphere during installation, service, or retirement of equipment. Therefore, R-22 must be recovered and recycled (for reuse in the same system), reclaimed (reprocessed to the same purity standard as new R-22), or destroyed. After 2020, the servicing of R-22-based systems will rely solely on recycled or reclaimed refrigerants. It is expected that reclamation and recycling will ensure that existing supplies of R-22 will last longer and be available to service a greater number of systems. As noted above, chemical manufacturers will no longer be able to produce, and companies will no longer be able to import, R-22 for use in new A/C equipment after 2010, but they can continue production and import of R-22 until 2020 for use in servicing existing equipment. Given this schedule, which was established in 1993, the transition away from R-22 to the use of ozone-friendly refrigerants should be smooth. For the next 10 years or more, R-22 should continue to be available for all systems that require R-22 for servicing. MY comments: I think it was Jan 1 , 2010 that new systems could not be installed with the r-22 in it. About 4 years ago the 20 some year old heat pump in my house went out. I had a choice of the r-22 or another type. I went with the r-22 as it operates at a lower pressure and less stress on the systems should let it last longer. I knew all about the phase out as I had to get licensed for the refrigerant where I work. I don't deal with the actual refrigerant, but do have to install instrumentation on the systems. If there was still much refrigerant in the system, he should have recycled it. Could have saved it in a seperate tank and taken it somewhere to reclaim it. If he just opened it to the air and let it all blead out, there is a big fine for it. Something like $ 10 to $ 30 thousand. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Cost of freon 22 | Home Repair | |||
Cost of freon 22 | Home Repair | |||
Cost of freon 22 | Home Repair | |||
AC low freon? | Home Repair | |||
Can I tell if there is freon in the AC? | Home Repair |