Electr. 14/3 wire under vinyl siding
I am installing an outide lite on a vinyl siding mounting block.
Electricity is available 5 feet away via a duplex outside GFI vinyl siding mounted outlet. Question: Can I run 14/3 under the vinyl siding connecting the source to the lite? If so, what type romex do I need? NM-B? tia |
#2
Posted to alt.home.repair
|
|||
|
|||
Electr. 14/3 wire under vinyl siding
|
#3
Posted to alt.home.repair
|
|||
|
|||
Electr. 14/3 wire under vinyl siding
replying to clare, Jeff Garlock wrote:
Any recommendation on the "steel protector" referenced above? Is there a specific brand or type? I am doing a similar project. -- for full context, visit https://www.homeownershub.com/mainte...ng-439435-.htm |
#4
Posted to alt.home.repair
|
|||
|
|||
Electr. 14/3 wire under vinyl siding
On Sat, 2 Nov 2019 02:14:01 +0000, Jeff Garlock
m wrote: replying to clare, Jeff Garlock wrote: Any recommendation on the "steel protector" referenced above? Is there a specific brand or type? I am doing a similar project. If you are protecting 5 feet of cable I doubt you are going to find anything off the shelf that works but you might find a strip of 16 gauge galvanized a couple inches wide in the trash at a metal fabricator. I would only use galvanized or stainless to avoid rust. I would still paint the galvanized (edges are not protected) |
#5
Posted to alt.home.repair
|
|||
|
|||
Electr. 14/3 wire under vinyl siding
On Saturday, November 2, 2019 at 8:48:20 AM UTC-4, wrote:
On Sat, 2 Nov 2019 02:14:01 +0000, Jeff Garlock m wrote: replying to clare, Jeff Garlock wrote: Any recommendation on the "steel protector" referenced above? Is there a specific brand or type? I am doing a similar project. If you are protecting 5 feet of cable I doubt you are going to find anything off the shelf that works but you might find a strip of 16 gauge galvanized a couple inches wide in the trash at a metal fabricator. I would only use galvanized or stainless to avoid rust. I would still paint the galvanized (edges are not protected) Home Depot sells small pieces of sheet metal. |
#6
Posted to alt.home.repair
|
|||
|
|||
Electr. 14/3 wire under vinyl siding
On Sat, 2 Nov 2019 07:42:37 -0700 (PDT), trader_4
wrote: On Saturday, November 2, 2019 at 8:48:20 AM UTC-4, wrote: On Sat, 2 Nov 2019 02:14:01 +0000, Jeff Garlock m wrote: replying to clare, Jeff Garlock wrote: Any recommendation on the "steel protector" referenced above? Is there a specific brand or type? I am doing a similar project. If you are protecting 5 feet of cable I doubt you are going to find anything off the shelf that works but you might find a strip of 16 gauge galvanized a couple inches wide in the trash at a metal fabricator. I would only use galvanized or stainless to avoid rust. I would still paint the galvanized (edges are not protected) Home Depot sells small pieces of sheet metal. They don't have 16 ga galvanized and this is really the kind of thing they away at a metal fabricator. Even if you had do buy it they would only want $5 or something unless they have a minimum shop charge. I have always been able to jest talk them out of things like this. Don't go in the office, just look in the dumpster or scrap pile. You just don't say it is trash. They will correct you ;-) The other option is a sleeve of EMT (conduit). That is only $3 a stick or something. He also should be using UF cable, not NM. |
#7
Posted to alt.home.repair
|
|||
|
|||
Electr. 14/3 wire under vinyl siding
On Sat, 2 Nov 2019 07:42:37 -0700 (PDT), trader_4
wrote: On Saturday, November 2, 2019 at 8:48:20 AM UTC-4, wrote: On Sat, 2 Nov 2019 02:14:01 +0000, Jeff Garlock m wrote: replying to clare, Jeff Garlock wrote: Any recommendation on the "steel protector" referenced above? Is there a specific brand or type? I am doing a similar project. If you are protecting 5 feet of cable I doubt you are going to find anything off the shelf that works but you might find a strip of 16 gauge galvanized a couple inches wide in the trash at a metal fabricator. I would only use galvanized or stainless to avoid rust. I would still paint the galvanized (edges are not protected) Home Depot sells small pieces of sheet metal. I was really just answering the question asked but it does beg the question, is there an extra 6 cu/in left over in the box he wants to hit and is there a chance he can just fish the RX down the inside of the wall. That is a far less invasive solution. There are tricks to do that. The hardest part may be picking the knock out out of the box from inside. |
#8
Posted to alt.home.repair
|
|||
|
|||
Electr. 14/3 wire under vinyl siding
wrote in message ... I am installing an outide lite on a vinyl siding mounting block. Electricity is available 5 feet away via a duplex outside GFI vinyl siding mounted outlet. Question: Can I run 14/3 under the vinyl siding connecting the source to the lite? If so, what type romex do I need? NM-B? *Use MC cable. Attach a bonding bushing to the MC connector and put a grounding pigtail on the bushing. You may need to use an angle connector to go into the siding block from behind. Why do you need a 3 wire? |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
J-siding missing on vinyl siding next to chimney: pics | Home Repair | |||
100 yr old house, stucco over wood siding - now vinyl siding on top? | Home Repair | |||
Vinyl siding to replace wood siding. | Home Repair | |||
Styrofoam Between Present T1-11 Siding & New Vinyl Siding: Worth It ? | Home Repair | |||
Styrofoam Between Present T1-11 Siding & New Vinyl Siding: Worth It ? | Home Ownership |