Hi there,

I own a duplex that has hydronic heating with an oil-fired boiler. The
problem is that there is a single oil tank for the whole duplex, and as
the owner (living in the lower duplex) I have no control over how much
tenants (living in the upper duplex) consume in terms of heating. The
boiler is relatively new and I would hate to have to replace it, but I am
looking for a way to separate the heating either switching to gas or
electric, so that each living unit is independent.
Does anyone know if this can be done without replacing the boiler?

Any ideas would be appreciated.

Thanks.


##-----------------------------------------------##
Delivered via http://thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 358118 messages and counting!
##-----------------------------------------------##
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Replace oil heating but keep boiler

On Jun 9, 6:20*pm, (lakeshow)
wrote:
-------------------------------------

Hi there,

I own a duplex that has hydronic heating with an oil-fired boiler. The
problem is that there is a single oil tank for the whole duplex, and as
the owner (living in the lower duplex) I have no control over how much
tenants (living in the upper duplex) consume in terms of heating. The
boiler is relatively new and I would hate to have to replace it, but I am
looking for a way to separate the heating either switching to gas or
electric, so that each living unit is independent.
Does anyone know if this can be done without replacing the boiler?

Any ideas would be appreciated.

Thanks.

##-----------------------------------------------##
Delivered via *http://thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 358118 messages and counting!
##-----------------------------------------------##


A few Danfoss TRVs might do it.
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 500
Default Replace oil heating but keep boiler

On Jun 9, 6:49*pm, ransley wrote:
On Jun 9, 6:20*pm, (lakeshow)
wrote:



-------------------------------------


Hi there,


I own a duplex that has hydronic heating with an oil-fired boiler. The
problem is that there is a single oil tank for the whole duplex, and as
the owner (living in the lower duplex) I have no control over how much
tenants (living in the upper duplex) consume in terms of heating. The
boiler is relatively new and I would hate to have to replace it, but I am
looking for a way to separate the heating either switching to gas or
electric, so that each living unit is independent.
Does anyone know if this can be done without replacing the boiler?


Any ideas would be appreciated.


Thanks.


##-----------------------------------------------##
Delivered via *http://thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 358118 messages and counting!
##-----------------------------------------------##


A few Danfoss TRVs might do it.


Ok, I'll bite - How does adding t-stats to each radiator or baseboard
separate the billing for the heat between the two units?


For the OP, here are some options -

1) Add a 2nd boiler, gas or oil, and separate the plumbing from the
baseboard or radiators, probably easiest with PEX.

2) Disconnect the baseboards or radiators in the tenant's unit and
replace them with electric baseboards. This will probably cost more
to operate.

3) Disconnect the baseboards or radiators and have a separate gas
forced air furnace installed in the attic.

Given the choices, I would prefer #1.

JK
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 11,640
Default Replace oil heating but keep boiler


"lakeshow" wrote in message
...


-------------------------------------

Hi there,

I own a duplex that has hydronic heating with an oil-fired boiler. The
problem is that there is a single oil tank for the whole duplex, and as
the owner (living in the lower duplex) I have no control over how much
tenants (living in the upper duplex) consume in terms of heating. The
boiler is relatively new and I would hate to have to replace it, but I am
looking for a way to separate the heating either switching to gas or
electric, so that each living unit is independent.
Does anyone know if this can be done without replacing the boiler?

Any ideas would be appreciated.


Not being able to see how the setup is, it is not possible to say for sure,
but most likely it can be separated. Given enough time and money, most
anything like that can be done.

Assuming each has a completely different zone piping, those pipes can be
re-routed to another smaller boiler. Does each have a separate how water
supply too?

Electric heat will most likely require an upgrade on the service to 200A if
you have less. It is also expensive to operate in most areas. Gas service
may or may not be expensive but utility companies often offer deals for
conversions or new customers.

Including the cost of heat int he lease can be risky if people abuse the use
of heat, but it will cost thousands to add a new boiler and associated
piping. Could be a long payback. Your old boiler may have to be de-rated
also if you reduce the load considerably.


  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 10,530
Default Replace oil heating but keep boiler

Please learn to post to usenet the regular way.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"lakeshow" wrote in
message
...


-------------------------------------

Hi there,

I own a duplex that has hydronic heating with an oil-fired
boiler. The
problem is that there is a single oil tank for the whole
duplex, and as
the owner (living in the lower duplex) I have no control
over how much
tenants (living in the upper duplex) consume in terms of
heating. The
boiler is relatively new and I would hate to have to replace
it, but I am
looking for a way to separate the heating either switching
to gas or
electric, so that each living unit is independent.
Does anyone know if this can be done without replacing the
boiler?

Any ideas would be appreciated.

Thanks.


##-----------------------------------------------##
Delivered via http://thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 358118 messages and counting!
##-----------------------------------------------##




  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 959
Default Replace oil heating but keep boiler


"lakeshow" wrote in message
...


-------------------------------------

Hi there,

I own a duplex that has hydronic heating with an oil-fired boiler. The
problem is that there is a single oil tank for the whole duplex, and as
the owner (living in the lower duplex) I have no control over how much
tenants (living in the upper duplex) consume in terms of heating. The
boiler is relatively new and I would hate to have to replace it, but I am
looking for a way to separate the heating either switching to gas or
electric, so that each living unit is independent.
Does anyone know if this can be done without replacing the boiler?

Any ideas would be appreciated.

Thanks.


##-----------------------------------------------##
Delivered via http://thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 358118 messages and counting!
##-----------------------------------------------##


Put one of those locking plastic boxes (like you see in schools , hospitals
and other commercial buildings) over the thermostats and set it at 68
degrees....

  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Replace oil heating but keep boiler

On Jun 9, 7:59*pm, Big_Jake wrote:
On Jun 9, 6:49*pm, ransley wrote:





On Jun 9, 6:20*pm, (lakeshow)
wrote:


-------------------------------------


Hi there,


I own a duplex that has hydronic heating with an oil-fired boiler. The
problem is that there is a single oil tank for the whole duplex, and as
the owner (living in the lower duplex) I have no control over how much
tenants (living in the upper duplex) consume in terms of heating. The
boiler is relatively new and I would hate to have to replace it, but I am
looking for a way to separate the heating either switching to gas or
electric, so that each living unit is independent.
Does anyone know if this can be done without replacing the boiler?


Any ideas would be appreciated.


Thanks.


##-----------------------------------------------##
Delivered via *http://thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 358118 messages and counting!
##-----------------------------------------------##


A few Danfoss TRVs might do it.


Ok, I'll bite - How does adding t-stats to each radiator or baseboard
separate the billing for the heat between the two units?

For the OP, here are some options -

1) Add a 2nd boiler, gas or oil, and separate the plumbing from the
baseboard or radiators, probably easiest with PEX.

2) Disconnect the baseboards or radiators in the tenant's unit and
replace them with electric baseboards. *This will probably cost more
to operate.

3) Disconnect the baseboards or radiators and have a separate gas
forced air furnace installed in the attic.

Given the choices, I would prefer #1.

JK- Hide quoted text -

- Show quoted text -


It wont separate billing it controls overheating. Its a tenant and he
has to supply a certain amount of heat, Thousands for the convienence
of a separate bill doesnt pay off, insulation does. Tenant pays heat,
rents are less.
  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,500
Default Replace oil heating but keep boiler

On Jun 9, 9:57*pm, "benick" wrote:
"lakeshow" wrote in message

...







-------------------------------------


Hi there,


I own a duplex that has hydronic heating with an oil-fired boiler. The
problem is that there is a single oil tank for the whole duplex, and as
the owner (living in the lower duplex) I have no control over how much
tenants (living in the upper duplex) consume in terms of heating. The
boiler is relatively new and I would hate to have to replace it, but I am
looking for a way to separate the heating either switching to gas or
electric, so that each living unit is independent.
Does anyone know if this can be done without replacing the boiler?


Any ideas would be appreciated.


Thanks.


##-----------------------------------------------##
Delivered via *http://thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 358118 messages and counting!
##-----------------------------------------------##


Put one of those locking plastic boxes (like you see in schools , hospitals
and other commercial buildings) over the thermostats and set it at 68
degrees....- Hide quoted text -

- Show quoted text -



I'd buy a good setback thermostat for the rental unit. Program it
for them, show them how to use it and explain that the oil bill plays
a large part in determining if you need to raise their rent. Then,
keep an eye on the oil bill. Assuming you have some historical data,
you should be able to tell if the bills are excessively high. If
they are, then just raise the rent by enough to offset it and tell
them why the rent is being increased.

As others have suggested, you CAN do just about anything. But given
that you have a new boiler, installing a seperate heating system for
the rental unit is going to have a very long payback. Plus, you'd
have 2 systems to maintain, which will cost more than one.

Also, since the rental is on the second level, their heating reqts are
probably going to be less than yours on the first floor. So, if you
go with two seperate systems, you will probably still have a bigger
oil bill than they do.
  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,500
Default Replace oil heating but keep boiler

On Jun 10, 1:21*pm, Hipupchuck wrote:
lakeshow wrote:

-------------------------------------


Hi there,


I own a duplex that has hydronic heating with an oil-fired boiler. The
problem is that there is a single oil tank for the whole duplex, and as
the owner (living in the lower duplex) I have no control over how much
tenants (living in the upper duplex) consume in terms of heating. The
boiler is relatively new and I would hate to have to replace it, but I am
looking for a way to separate the heating either switching to gas or
electric, so that each living unit is independent.
Does anyone know if this can be done without replacing the boiler?


Any ideas would be appreciated.


Thanks.


##-----------------------------------------------##
Delivered via *http://thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 358118 messages and counting!
##-----------------------------------------------##


You give them a separate zone and thermostat. Then you put in a second
oil tank for them. They fill that one. Then you put in an oil valve that
draws from their tank when their zone calls for heat and draws from your
oil tank when your zone calls for heat and draws from both when both are
calling for heat. If their tank is empty then no heat for them.


Sounds to me like no heat for everybody when the tenant's tank runs
dry, because as long as their apartment calls for heat, the furnace is
going to be sucking air from the empty tank and then tripping off.
Also, how are you going to ensure the oil flow when it's drawing from
both tanks is divided up proportionaly? It's not even clear exactly
what the right percentage should be, let alone what might happen with
2 tanks just plumbed together with valves.



You may have to invent that type of oil valve.- Hide quoted text -

- Show quoted text -


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Boiler/central heating - replace? tvmo UK diy 35 April 7th 08 09:40 PM
boiler question: put in new block assembly or replace boiler? [email protected] Home Repair 0 January 5th 07 04:36 AM
Fix or replace? (CH boiler) Tim Downie UK diy 38 March 12th 06 08:13 PM
Complicated central Heating; Back-Boiler and Combi-Boiler tfc715 UK diy 1 February 3rd 05 05:30 PM
Combi Boiler woes - first heating & no DHW, now DHW and no heating.... RichardS UK diy 8 April 8th 04 09:52 PM


All times are GMT +1. The time now is 09:12 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"