Why Vacuum Relief Valves on Water Heaters
I was advised to also replace the vacuum relief valve when I recently
had to replace our home's (leaking) water heater. Since the part was cheap enough and I'd never thought to replace it in the 23 years (and two previous water heater replacements by me.) since its original installation, I went ahead and bought one. Then I started wondering just what conditions would cause enough negative pressure to collapse a water heater tank. ******* The description of Watts' vacuum relief valve reads: Series N36 Watts Water Service Vacuum Relief Valves are used in water heater/tank applications to automatically allow air to enter into the piping system to prevent vacuum conditions that could siphon the water from the system and damage water heater/tank equipment. ******* Since our home is at the crest of hill, I suppose that if the city pumping system went bad, or a water main below us burst there could be a long enough column of water "hanging down" to pull up to one atmosphere of vacuum in our home's supply, which is probably more than enough to collapse a water heater tank. A plumber I asked said that a fire engine pumping out of a nearby hydrant could also create a negative pressure in the main. Are those the expected kind of things a vacuum relief valve protects against? Thanks guys, and Happy New Year, Jeff -- Jeffry Wisnia (W1BSV + Brass Rat '57 EE) The speed of light is 1.8*10^12 furlongs per fortnight. |
#2
Posted to alt.home.repair
|
|||
|
|||
Why Vacuum Relief Valves on Water Heaters
On Dec 29, 1:04*pm, Jeff Wisnia wrote:
I was advised to also replace the vacuum relief valve when I recently had to replace our home's (leaking) water heater. Since the part was cheap enough and I'd never thought to replace it in the 23 years (and two previous water heater replacements by me.) since its original installation, I went ahead and bought one. Then I started wondering just what conditions would cause enough negative pressure to collapse a water heater tank. ******* The description of Watts' vacuum relief valve reads: Series N36 Watts Water Service Vacuum Relief Valves are used in water heater/tank applications to automatically allow air to enter into the piping system to prevent vacuum conditions that could siphon the water from the system and damage water heater/tank equipment. ******* Since our home is at the crest of hill, I suppose that if the city pumping system went bad, or a water main below us burst there could be a long enough column of water "hanging down" to pull up to one atmosphere of vacuum in our home's supply, which is probably more than enough to collapse a water heater tank. A plumber I asked said that a fire engine pumping out of a nearby hydrant could also create a negative pressure in the main. Are those the expected kind of things a vacuum relief valve protects against? Thanks guys, and Happy New Year, Jeff -- Jeffry Wisnia (W1BSV + Brass Rat '57 EE) The speed of light is 1.8*10^12 furlongs per fortnight. I would guess that the main concern is not siphoning action collapsing the tank, but it taking enough of the water out so that either the electric elements then burn out or steam is generated with a gas unit, exploding the tank. Of course the TPR valve is there to hopefully prevent the latter. Here in NJ, I've never seen one used, even in new construction. So, apparently here they are not required by code. The first time I ever even saw one on a water heater was on a recent episode of This Old House, when they were removing a water heater. All in all, unless I'm missing something, I don't see the need. |
#3
Posted to alt.home.repair
|
|||
|
|||
Why Vacuum Relief Valves on Water Heaters
|
#4
Posted to alt.home.repair
|
|||
|
|||
Why Vacuum Relief Valves on Water Heaters
It was also mentioned to me by my plumber aquaintance that present codes here in Red Sox Nation require power disconnect switches adjacent to new electric water heater installations for the same reason they've been used for a long time near outside AC units. They can prevent repair folks from getting zapped or whacked when someone else decides to flip a panel breaker back on while they're messing around inside the equipment. I wonder what's next? Jeff -- Jeffry Wisnia All new vehicles will come with no tamper GPS receivers. if tye GPS breaks the vehicle doesnt run. it checks the speed limit on the road you are on and acting like a govenor prevents speeding. in a chase situation where police are chasing a vehicle they send out a signal, all close by vehicles drop to 5 MPH limit national tracking of all people begins, technically it already has with cell phones. every citizen gets a new national ID card, in exchange for DNA sample, picture and fingerprints, plus retinal scan. great for searching out bad guys. making credit card purachase? just one card will work for any person, with fingerprint scan and id number charge gets applied to your account. cash is becoming obsolete for better tracking. dont laugh its all for our safety |
#5
Posted to alt.home.repair
|
|||
|
|||
Why Vacuum Relief Valves on Water Heaters
|
#6
Posted to alt.home.repair
|
|||
|
|||
Why Vacuum Relief Valves on Water Heaters
mm wrote:
On Mon, 29 Dec 2008 10:10:21 -0800 (PST), wrote: I would guess that the main concern is not siphoning action collapsing the tank, but it taking enough of the water out so that either the electric elements then burn out If siphoning would suck enough water out to uncover an electric heating element, having a vacuum relief valve wouldn't help. It doesn't just make the vacuum disappear. It gets rid of it by allowing air to enter. I'll have to take issue with that statement, mm. If something going wrong with the home's water main supply causes a negative pressure at the heater's cold water inlet and a hot water faucet is opened, water could get sucked out of the tank (and the hot water pipes coming from the open faucet) through the heater's dip tube, lowering the level in the tank down to the bottom of the dip tube, which will certainly expose the element(s). A vacuum relief valve teed onto the heater's inlet pipe "breaks" the vacuum right there so water won't get sucked out of the tank. Capice, mm? Jeff -- Jeffry Wisnia (W1BSV + Brass Rat '57 EE) The speed of light is 1.98*10^14 fathoms per fortnight. or steam is generated with a gas unit, exploding the tank. I don't know about gas, except the kind we can't discuss politely. Of course the TPR valve is there to hopefully prevent the latter. Here in NJ, I've never seen one used, even in new construction. So, apparently here they are not required by code. The first time I ever even saw one on a water heater was on a recent episode of This Old House, when they were removing a water heater. All in all, unless I'm missing something, I don't see the need. |
#8
Posted to alt.home.repair
|
|||
|
|||
Why Vacuum Relief Valves on Water Heaters
On Dec 29, 4:25*pm, " wrote:
dont laugh its all for our safety Ha ha ha. Too bad it will take two people for every one of us to effectively monitor our activities to the extent that the "big brother is watching" conspiracy theorists often spout off about. Soooo, who is paying the salaries of the 600 million "big brothers" watching the 300 million of us? Where are they hiding 600 million government employees? |
#9
Posted to alt.home.repair
|
|||
|
|||
Why Vacuum Relief Valves on Water Heaters
On Tue, 30 Dec 2008 00:16:49 -0500, Jeff Wisnia
wrote: mm wrote: On Mon, 29 Dec 2008 10:10:21 -0800 (PST), wrote: I would guess that the main concern is not siphoning action collapsing the tank, but it taking enough of the water out so that either the electric elements then burn out If siphoning would suck enough water out to uncover an electric heating element, having a vacuum relief valve wouldn't help. It doesn't just make the vacuum disappear. It gets rid of it by allowing air to enter. I'll have to take issue with that statement, mm. If something going wrong with the home's water main supply causes a negative pressure at the heater's cold water inlet and a hot water faucet is opened, water could get sucked out of the tank (and the hot water pipes coming from the open faucet) through the heater's dip tube, lowering the level in the tank down to the bottom of the dip tube, which will certainly expose the element(s). A vacuum relief valve teed onto the heater's inlet pipe "breaks" the vacuum right there so water won't get sucked out of the tank. Capice, mm? Jeff I get it. Thanks. |
#10
Posted to alt.home.repair
|
|||
|
|||
Why Vacuum Relief Valves on Water Heaters
On Dec 30, 1:39�pm, wrote:
On Dec 29, 4:25�pm, " wrote: dont laugh its all for our safety Ha ha ha. Too bad it will take two people for every one of us to effectively monitor our activities to the extent that the "big brother is watching" conspiracy theorists often spout off about. Soooo, who is paying the salaries of the 600 million "big brothers" watching the 300 million of us? Where are they hiding 600 million government employees? Artifical intelligence, computers are already listening in for key words phrases etc. ones of interest get reviewed by humans. it is true that every country tried this in the past failed because of costs and inhibiting creativity by the population. a national DNA data base will help find murders rapists etc. no I am NOT in favor of big brother! just reporting on whats coming |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Washing Machine Water Inlet Valves - Cheap Source of Solonoid Control Valves? | Home Repair | |||
water pressure relief valve strainer | Home Repair | |||
pressure relief valve releasing water | Home Repair | |||
Water heater relief valve -- POW! | Home Repair | |||
Hot water tank pressure relief | Home Repair |