Inserting a tee in a 1/2" water line
Hi,
When cutting into a 1/2" water line to install a tee, what length should one cut out? I took my measurements and it seems like about an inch, but I decided to ask anyway. The pipe I'm cutting into has a turn, so I'm guessing I have some flexibility. Also, I presume it's a good idea to remove slight less than necessary than slightly more than necessary. Thanks! Aaron |
#2
Posted to alt.home.repair
|
|||
|
|||
Inserting a tee in a 1/2" water line
On Sep 6, 9:26*pm, Aaron Fude wrote:
Hi, When cutting into a 1/2" water line to install a tee, what length should one cut out? I took my measurements and it seems like about an inch, but I decided to ask anyway. The pipe I'm cutting into has a turn, so I'm guessing I have some flexibility. Also, I presume it's a good idea to remove slight less than necessary than slightly more than necessary. Thanks! Aaron If there is some movement in the pipe I only make one cut. |
#3
Posted to alt.home.repair
|
|||
|
|||
Inserting a tee in a 1/2" water line
On Sep 6, 4:26*pm, Aaron Fude wrote:
Hi, When cutting into a 1/2" water line to install a tee, what length should one cut out? I took my measurements and it seems like about an inch, but I decided to ask anyway. The pipe I'm cutting into has a turn, so I'm guessing I have some flexibility. Also, I presume it's a good idea to remove slight less than necessary than slightly more than necessary. Thanks! Aaron Are you talking about copper tube (5/8" od x ~1/2" id) or galvanized pipe? If it is copper tube & you have will have enough play after the tube is cut out about 1/2" to 5/8" (that's the approximate distance between seated tube ends in a Tee) repair the system by installing the Tee and two copper street elbows......the mechanical fit up will be easy if yoy get about 1/2" or so of offset. Once you get the fittings ready to install....... how it goes together will be evident. cheers Bob |
#4
Posted to alt.home.repair
|
|||
|
|||
Inserting a tee in a 1/2" water line
I think one early step is to research, and see what kind of pipe or tubing
you have. Copper, pex, braided flex, Ufukt, galvanized. All use different methods of inserting a Tee. -- Christopher A. Young Learn more about Jesus www.lds.org .. "Aaron Fude" wrote in message ... Hi, When cutting into a 1/2" water line to install a tee, what length should one cut out? I took my measurements and it seems like about an inch, but I decided to ask anyway. The pipe I'm cutting into has a turn, so I'm guessing I have some flexibility. Also, I presume it's a good idea to remove slight less than necessary than slightly more than necessary. Thanks! Aaron |
#5
Posted to alt.home.repair
|
|||
|
|||
Inserting a tee in a 1/2" water line
In article ,
"Stormin Mormon" wrote: I think one early step is to research, and see what kind of pipe or tubing you have. Copper, pex, braided flex, Ufukt, galvanized. All use different methods of inserting a Tee. Mr. Fude posted a link to a picture of the pipe in question. |
#6
Posted to alt.home.repair
|
|||
|
|||
Inserting a tee in a 1/2" water line
On Sep 7, 3:06*pm, Smitty Two wrote:
In article , *"Stormin Mormon" wrote: I think one early step is to research, and see what kind of pipe or tubing you have. Copper, pex, braided flex, Ufukt, galvanized. All use different methods of inserting a Tee. Mr. Fude posted a link to a picture of the pipe in question. ..........Mr. Fude posted a link to a picture of the pipe in question......... Yeah, that stuff looked like threaded black iron. Why the new thread? cheers Bob |
#7
Posted to alt.home.repair
|
|||
|
|||
Inserting a tee in a 1/2" water line
Different conversation. I remember the picture that Elmer Fude posted. But,
it wasn't the half inch water line. -- Christopher A. Young Learn more about Jesus www.lds.org .. "Smitty Two" wrote in message news In article , "Stormin Mormon" wrote: I think one early step is to research, and see what kind of pipe or tubing you have. Copper, pex, braided flex, Ufukt, galvanized. All use different methods of inserting a Tee. Mr. Fude posted a link to a picture of the pipe in question. |
#8
Posted to alt.home.repair
|
|||
|
|||
Inserting a tee in a 1/2" water line
Maybe Elmer Fude is a busy handy man?
-- Christopher A. Young Learn more about Jesus www.lds.org .. "BobK207" wrote in message ... Mr. Fude posted a link to a picture of the pipe in question. ..........Mr. Fude posted a link to a picture of the pipe in question......... Yeah, that stuff looked like threaded black iron. Why the new thread? cheers Bob |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Newer appliances - less "load" on power line? | Home Repair | |||
using existing 3/8" flex copper line for fridge ice/water | Home Repair | |||
the "ACP production line" and "Aluminum coil coating line" equipment | Home Repair | |||
Circuit to connect "Soundblaster" electret microphone to line-input | Electronics | |||
What AWG is "Drop on ground" phone line wire? | Electronics Repair |