On Mar 22, 3:43�am, mm wrote:
On Thu, 22 Mar 2007 01:49:48 GMT, "Toller" wrote: I had a second pump put in a corner that wasn't draining properly. *The guy cut out a square with a circular saw, dug a pit, and worked a plastic basin in. * A lot of work, but nothing too difficult. *The dust was HORRIBLE. I forgot about dust. *Wear a good dust maak and probably keep the vacuum running all the time, to clean the air. *If there were a window, I'd recommend a fan blowing out a window. *(I did this when I sanded my floor, with an old 14 inch fan from the trash. *It ran all day with no problem, and then failed just as I was about to turn it off.) I had him plumb it to the sanitary sewer, which I later found out is illegal; but it only came on when the first pump was overwhelmed, so it i"m not in a position to judge, and the OP's basement might never get that wet, buy this sounds like an advantage over a regular pump and a backup, as opposed to the single pump I just recommended. *My pump has only been overwhelmed once in 28 years, but it would sure have been nice to have two pumps at that time. *(Or a bigger first pump. I suppose they sold one but I only looked for the same size I had since it had worked fine for the first 15 years. *Rusted through then but the new ones have plastic pipe at the water level and I think will last 2 or 3 times as long.) didn't amount to much.- Hide quoted text - - Show quoted text - Ahh the amount of dust from cutting concrete is WAY WORSE than sanding, jackhammer better choice. dust is abrasive, lightweight, goes into cloud might get in furnace etc. plus if you jackhammer the repaired concrete is way less likely to crack. thew nice smooth edge of masonary blade equals poor adhesion. ![]() ideally the underground drain runs to day light somewhere. gravity tends to be reliable. even if its a lot of digging you will appreciate knowing your sump cant fail. plus a 4 inch PVC line can carry way more water than a backup sump pump if you must go pump, do TWO, with seperate outlets, completely seperate everything. perhaps the primary draind into a downspout line? thake the backup thru the wall and let it spray out of side of home if the water will run away downhill. having just one pump or pump sharing lines etc leaves you more open to failure......... |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
They are burning under the river now, won't believe shoes later. | Woodworking | |||
cement and river sand??? | UK diy |