Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4
Default Steam Heat question

My home, built in 1931, was originally a coal fired two pipe steam
system. In the 70's the owner replaced coal with a weil mclain 76
series boiler. i believe my home has too many radiators (1500 sq ft
of steam edr) which is logical since energy was cheap and people slept
with windows open etc. On top of that, I believe my boiler is
oversized for the number of radiators I have. Originally my boiler
was fitted with a 4.25 gallon/hr nozzle. Now it is fitted with a 2.8
gph nozzle. right now i'm burning roughly 3000 galllons of oil per
year for a 4000 square foot house. Seems excessive to me. Even if I
reduce the size or amount my radiators wouldn't the existing piping
still require me to use a large boiler?

I'm thinking of switching to hot water but i understand that there are
pitfalls that need to be avoided. My radiators are connected at the
top and could be used for hot water. I would like to insulate my
house a little better and have a heat loss study performed before
switching to hot water so I can be sure that I have the proper size
boiler and correct number of radiators.

Does switching make sense? If so, does the large size of my steam
pipes eliminate the efficiency savings provided by a hot water
system. Could some sort of flexible plastic pipes be snaked through
my large steam pipes to neck them down ? That would also prevent
leakage problems.

Or an alternative would be to keep steam or a combinatio of steam on
my 2nd floor and hot water on the first since piping the first floor
would be easy from the basement.

  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 746
Default Steam Heat question

mike wrote:

My home, built in 1931, was originally a coal fired two pipe steam
system. In the 70's the owner replaced coal with a weil mclain 76
series boiler. i believe my home has too many radiators (1500 sq ft
of steam edr) which is logical since energy was cheap and people slept
with windows open etc. On top of that, I believe my boiler is
oversized for the number of radiators I have. Originally my boiler
was fitted with a 4.25 gallon/hr nozzle. Now it is fitted with a 2.8
gph nozzle. right now i'm burning roughly 3000 galllons of oil per
year for a 4000 square foot house. Seems excessive to me. Even if I
reduce the size or amount my radiators wouldn't the existing piping
still require me to use a large boiler?

I'm thinking of switching to hot water but i understand that there are
pitfalls that need to be avoided. My radiators are connected at the
top and could be used for hot water. I would like to insulate my
house a little better and have a heat loss study performed before
switching to hot water so I can be sure that I have the proper size
boiler and correct number of radiators.

Does switching make sense? If so, does the large size of my steam
pipes eliminate the efficiency savings provided by a hot water
system. Could some sort of flexible plastic pipes be snaked through
my large steam pipes to neck them down ? That would also prevent
leakage problems.

Or an alternative would be to keep steam or a combinatio of steam on
my 2nd floor and hot water on the first since piping the first floor
would be easy from the basement.


My take: Put your money into as much insulation as you can
reasonably afford.

Trying to make tiny incremental increases in heating plant
efficiency is attacking the wrong end of the problem.

After insulating, get the heating costs for another season
before deciding what mechanical changes to make.
I don't personally think going thru the massive effort to
switch steam to hydronic will save a thing.

Jim
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 5,823
Default Steam Heat question


"mike" wrote in message
oups.com...
Now it is fitted with a 2.8
gph nozzle. right now i'm burning roughly 3000 galllons of oil per
year for a 4000 square foot house. Seems excessive to me. Even if I
reduce the size or amount my radiators wouldn't the existing piping
still require me to use a large boiler?


You are going about this the wrong way. No matter what type of heat you
have, no matter how large the heater, that is not the main culprit. I don't
know where you live but that amount of oil is not uncommon on a house that
size in a cold climate.

First, think about how the heating system works. You have a thermostat.
When the temperature drops, the thermostat sends a signal to the heater to
start up. When the temperature goes up, it tells the heater to stop. If
you have a heater that is small, it may take a long time for that to happen.
If you have a heater that is too large, the heater will go off in a short
time. In either case, the amount of energy needed to satisfy the thermostat
is about the same.

Once you burn fuel to make heat, you want to keep it. How is the
insulation, windows, doors, etc? Before spending a lot of money to change
the boiler, find out where the heat is going and stop it from going. A 1931
house had no insulation. If some has been added, then yes, you can get away
with a smaller boiler but first, put that money into saving the heat and
then you can change out the mechanicals if needed and pay for it with the
savings.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Steam Heat question mike Home Repair 0 February 21st 07 09:51 PM
Steam Heat Hissing Sound Bnchs400 Home Repair 2 January 28th 06 07:39 AM
Steam Heat Costs [email protected] Home Repair 23 January 18th 06 02:34 AM
flushing boiler / steam heat [email protected] Home Ownership 2 January 9th 05 02:55 PM


All times are GMT +1. The time now is 03:01 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"