Default Water heater confuses me; which thermostat?

I can't figure out which thermostat needs replacing, or why, or maybe
it is some other part:

My Sears model 153.318560 52 Gal. Power Miser 8+ electric water heater
(which looks an awful lot like an AO Smith heater) turned off and I
had no hot water. I reset the heat limit switch of the top
thermostat, and later I measured the water temp at 170 degrees. It
turned off again. This time I had to reset both the top and bottom
thermostats, and I later measured the temp at 180 degrees.

That second time, by watching the heater and the power meter outside,
I saw that the red light, which means the top element is running,
stayed on for 20 minutes or a little less, and that the bottom element
was working. I don't think 20 minutes would be enough to raise the
temp to 170 or 180, so I decided the bottom thermostat was bad and I
replaced it.

Now** the red light doesn't even go on at all, but I watched closely
and checked early and the temp got up to 160 before I turned it off.

The only thing left to replace is the top thermostat, but I'd like to
understand how that could be the problem, or be told what the problem
is before I replace it. Any ideas??

I checked for a short between the heating element and ground. There
is none.


**After the bottom thermostat was out, but before the new one had come
in, I wanted to take a bath, so I turned the water heater on with no
bottom thermostat. The red light went on and I soon had enough hot
water for 3 inches in the tub. But when I tried that the following
day, when I had used all the hot water, nothing happened. The red
light didnt' go on, and it didn't go on the following day after I had
installed the new bottom thermostat. Did I break something by running
without the bottom thermostat?? How would that be worse than running
it with a broken bottom element? (the bottom element circuit is a
simple series circuit with the thermostat and the heating element.)
  #2   Report Post  
Posted to alt.home.repair
RBM RBM is offline
external usenet poster
 
Posts: 1,690
Default Water heater confuses me; which thermostat?

I don't see where you determined that you had power to the lower element, or
even the lower thermostat. Typical wiring would have one leg of the circuit
going to each element. The second leg of the circuit goes to the upper
element via the upper thermostat. Once the upper thermostat is satisfied, it
disconnects from the upper element and sends that leg to the lower
thermostat, which is normally closed and sends the leg to the lower element.
The lower element heats until its thermostat is satisfied or the upper
thermostat calls for heat



"mm" wrote in message
...
I can't figure out which thermostat needs replacing, or why, or maybe
it is some other part:

My Sears model 153.318560 52 Gal. Power Miser 8+ electric water heater
(which looks an awful lot like an AO Smith heater) turned off and I
had no hot water. I reset the heat limit switch of the top
thermostat, and later I measured the water temp at 170 degrees. It
turned off again. This time I had to reset both the top and bottom
thermostats, and I later measured the temp at 180 degrees.

That second time, by watching the heater and the power meter outside,
I saw that the red light, which means the top element is running,
stayed on for 20 minutes or a little less, and that the bottom element
was working. I don't think 20 minutes would be enough to raise the
temp to 170 or 180, so I decided the bottom thermostat was bad and I
replaced it.

Now** the red light doesn't even go on at all, but I watched closely
and checked early and the temp got up to 160 before I turned it off.

The only thing left to replace is the top thermostat, but I'd like to
understand how that could be the problem, or be told what the problem
is before I replace it. Any ideas??

I checked for a short between the heating element and ground. There
is none.


**After the bottom thermostat was out, but before the new one had come
in, I wanted to take a bath, so I turned the water heater on with no
bottom thermostat. The red light went on and I soon had enough hot
water for 3 inches in the tub. But when I tried that the following
day, when I had used all the hot water, nothing happened. The red
light didnt' go on, and it didn't go on the following day after I had
installed the new bottom thermostat. Did I break something by running
without the bottom thermostat?? How would that be worse than running
it with a broken bottom element? (the bottom element circuit is a
simple series circuit with the thermostat and the heating element.)



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
tankless water heater vs. small water heater. Spider Home Repair 7 October 14th 14 12:03 AM
electric water heater headache tcl Home Ownership 1 October 6th 06 07:19 PM
water cooler, water coolers, water dispenser, water dispensers,bottleless water cooler,bottleless water coolers,bottleless water dispenser,bottleless water dispensers water coolers UK diy 3 January 5th 06 08:23 PM
Water heater leak? Jim Z Home Repair 1 July 18th 04 01:57 PM
I need a little advice on running waterlines in an uninsulated crawlspace ozark Home Repair 12 January 29th 04 05:23 AM


All times are GMT +1. The time now is 12:05 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"