Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1
Default Water Pressure problem

My home is two stories, with a basement, in the Northeast. Public
water enters the basement, then there is a ball valve, regulator,
meter, dual check valve, and another ball valve. Over the last several
weeks (since it has gotten cooler), most mornings there is no water at
the second story of the house. I then go to the first floor and try
the kitchen faucet. If there is good flow in the kitchen, it will
usually then charge the system up to the second floor. If there is no
water on the first floor, I have to go to the basement and close and
open the downstream ball valve. This will then charge the whole house.
Closing and opening the upstream ball valve in the basement does not
charge the system. I figure my problem is either the regulator or the
dual check valve. Anyone have an idea how to remedy this, and what is
a dual check valve?

  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 746
Default Water Pressure problem

todd wrote:

My home is two stories, with a basement, in the Northeast. Public
water enters the basement, then there is a ball valve, regulator,
meter, dual check valve, and another ball valve. Over the last several
weeks (since it has gotten cooler), most mornings there is no water at
the second story of the house. I then go to the first floor and try
the kitchen faucet. If there is good flow in the kitchen, it will
usually then charge the system up to the second floor. If there is no
water on the first floor, I have to go to the basement and close and
open the downstream ball valve. This will then charge the whole house.
Closing and opening the upstream ball valve in the basement does not
charge the system. I figure my problem is either the regulator or the
dual check valve. Anyone have an idea how to remedy this, and what is
a dual check valve?


http://www.crd.bc.ca/water/crossconn...checkvalve.htm

The valve is there to prevent water in the house lines from
backing up into the street Main.

I bet the dual check diaphragm is sticking under pressure.
Since you have a PRV and a check, the water heater must have
an expansion tank. Does yours? Without one, system
pressure can go above normal.

Another possible is that the street Main pressure suddenly
drops overnight, causing the check to jam.

Jim
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 521
Default Water Pressure problem

presuming your water line is not freezing, phone and ask the water
company to come and replace the meter for this specific problem.
when they come, be there to ask them your questions.
this will eliminate the meter as a possible problem.
if the problem continues, replace the next items one at a time.


todd wrote:
My home is two stories, with a basement, in the Northeast. Public
water enters the basement, then there is a ball valve, regulator,
meter, dual check valve, and another ball valve. Over the last several
weeks (since it has gotten cooler), most mornings there is no water at
the second story of the house. I then go to the first floor and try
the kitchen faucet. If there is good flow in the kitchen, it will
usually then charge the system up to the second floor. If there is no
water on the first floor, I have to go to the basement and close and
open the downstream ball valve. This will then charge the whole house.
Closing and opening the upstream ball valve in the basement does not
charge the system. I figure my problem is either the regulator or the
dual check valve. Anyone have an idea how to remedy this, and what is
a dual check valve?


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
AquaTherm Furnace - No Hot Water Issue David Home Repair 11 January 25th 18 08:44 PM
Question about water pressure in relation to valve and feeder pipe diameters... Ken Moiarty Home Repair 80 October 23rd 06 03:17 AM
Water Pump / Pressure Tank Problem !!!!!! James Nipper Home Ownership 6 June 28th 04 02:13 AM
Hot product for hot water ...products compaed [email protected] Home Repair 16 January 30th 04 04:07 AM