Plumbing drain question
I have a reasonably new split bath, with the vanity/sink in one room and tub
and toilet in the other. I want to install a very small pedistal sink between the toilet and bathtub. The wall is accessible thru a closet in the next room. Routing supply lines isnt't a problem. The drain pipe, though, is not easily accessible as it runs too far from the wall, under the floor. The only part I can tie the new sink into is the straight piece of PVC that connects the bathtub overflow to the tub drain. Is it OK to install a T there to drain the sink? The sink would have its own trap, but the wastewater would also go thru the tub trap. Thanks. -- -bye, Rick |
#2
Posted to alt.home.repair
|
|||
|
|||
Plumbing drain question
"Rick" wrote in message . .. I have a reasonably new split bath, with the vanity/sink in one room and tub and toilet in the other. I want to install a very small pedistal sink between the toilet and bathtub. The wall is accessible thru a closet in the next room. Routing supply lines isnt't a problem. The drain pipe, though, is not easily accessible as it runs too far from the wall, under the floor. The only part I can tie the new sink into is the straight piece of PVC that connects the bathtub overflow to the tub drain. Is it OK to install a T there to drain the sink? The sink would have its own trap, but the wastewater would also go thru the tub trap. Thanks. -- -bye, Rick No codes or standards permit such a connection. You will have to access the drain line after the tub trap and also meet the standards for venting to make a proper connection. You may need advice for your particular situation from someone who can actually see and evaluate it on site. Don Young |
#3
Posted to alt.home.repair
|
|||
|
|||
Plumbing drain question
"Don Young" wrote in message ... "Rick" wrote in message . .. I have a reasonably new split bath, with the vanity/sink in one room and tub and toilet in the other. I want to install a very small pedistal sink between the toilet and bathtub. The wall is accessible thru a closet in the next room. Routing supply lines isnt't a problem. The drain pipe, though, is not easily accessible as it runs too far from the wall, under the floor. The only part I can tie the new sink into is the straight piece of PVC that connects the bathtub overflow to the tub drain. Is it OK to install a T there to drain the sink? The sink would have its own trap, but the wastewater would also go thru the tub trap. Thanks. -- -bye, Rick No codes or standards permit such a connection. You will have to access the drain line after the tub trap and also meet the standards for venting to make a proper connection. You may need advice for your particular situation from someone who can actually see and evaluate it on site. Don Young Thanks, I didnt think so. I was hoping to save a few bucks, but want to do it right. Rick |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Yard drain system problem | Home Repair | |||
A quick plumbing question | Home Repair | |||
Drain Tile around house, new addition question | Home Repair | |||
basement plumbing question | Home Repair | |||
framing / plumbing question | Home Repair |