Moen 82470 no cold water pressure
I recently installed the model Moen 82470 in my bathroom. I had to
switch from a 3 control valve to a one control valve. I did all the soldering myself and everything works fine...well almost. I have no cold water pressure. I mean almost none. There is only a trickle of water that comes out. I've taken it apart and tested the cold water line for pressure without the valve, and when I put the valve on I have no cold water pressure. This is the second one I tried installing thinking that the first one I purchased was defective. Is there something I'm doing wrong? Can anybody point me in the right direction to look? Thank you, Ben |
#2
Posted to alt.home.repair
|
|||
|
|||
Moen 82470 no cold water pressure
You mention solder.
Are you protecting the unit from heat as per installation instructions? I was able to get a free cartridge from Moen by calling them - check their website. Do you have a shut off for the cold before the valve? Is it working - that is will water flow out the valve with the cartrige removed? Make sure that the cartrige moves freely within the valve. It may be stuck. Ben wrote: I recently installed the model Moen 82470 in my bathroom. I had to switch from a 3 control valve to a one control valve. I did all the soldering myself and everything works fine...well almost. I have no cold water pressure. I mean almost none. There is only a trickle of water that comes out. I've taken it apart and tested the cold water line for pressure without the valve, and when I put the valve on I have no cold water pressure. This is the second one I tried installing thinking that the first one I purchased was defective. Is there something I'm doing wrong? Can anybody point me in the right direction to look? Thank you, Ben |
#3
Posted to alt.home.repair
|
|||
|
|||
Moen 82470 no cold water pressure
Ben wrote: I recently installed the model Moen 82470 in my bathroom. I had to switch from a 3 control valve to a one control valve. I did all the soldering myself and everything works fine...well almost. I have no cold water pressure. I mean almost none. There is only a trickle of water that comes out. I've taken it apart and tested the cold water line for pressure without the valve, and when I put the valve on I have no cold water pressure. This is the second one I tried installing thinking that the first one I purchased was defective. Is there something I'm doing wrong? Can anybody point me in the right direction to look? Thank you, Ben is it an anti-scald valve? if so, are both hot and cold on and is the temperature setting properly set? |
#4
Posted to alt.home.repair
|
|||
|
|||
Moen 82470 no cold water pressure
"Ben" wrote in message ... I recently installed the model Moen 82470 in my bathroom. I had to switch from a 3 control valve to a one control valve. I did all the soldering myself and everything works fine...well almost. I have no cold water pressure. I mean almost none. There is only a trickle of water that comes out. I've taken it apart and tested the cold water line for pressure without the valve, and when I put the valve on I have no cold water pressure. This is the second one I tried installing thinking that the first one I purchased was defective. Is there something I'm doing wrong? Can anybody point me in the right direction to look? Thank you, Ben I had a similar problem with a Moen single handle faucet. Try swapping the feed lines going in where you can undo them with a wrench. Move the cold water supply to the hot side of the faucet and the hot supply to the cold side. When I did this, the problem stayed on the same side of the faucet. That is now the cold water came out fine and the hot was flow was poor. This verifies a bad casting in the faucet. A call to Moen explaining what I did got me a new replacement. Charlie |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Solar water heating and combi boilers | UK diy | |||
Instant Hot Water: Installing a Re-circulating System | Home Repair | |||
Water Pump / Pressure Tank Problem !!!!!! | Home Ownership | |||
Hot product for hot water ...products compaed | Home Repair | |||
hot water recirculator, instant hot water but not a water heating unit, saves water, gas, time, money | Home Repair |