If I connect the tub spout to the copper piping and run the water
completely thru the spout; water drips to the underneath ceiling. If I disconnect the tub spout so only the copper piping shows, and then run the water completely thru the spout; no water drips from underneath. Does anyone know what this could be? |
#2
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
Sounds like you may have a leak in the spout piping. When you install the
spout there is then enough backpressure to force the water out the leaking spot. Without the spout, then isn't enough backpressure to force the leak. Do you have any access to the back side of the tub. Like in a closet or something. You would need to cut an opening. If its in a closet, you can just make a nice panel to cover the cut out. Darrell "CJ" wrote in message oups.com... If I connect the tub spout to the copper piping and run the water completely thru the spout; water drips to the underneath ceiling. If I disconnect the tub spout so only the copper piping shows, and then run the water completely thru the spout; no water drips from underneath. Does anyone know what this could be? |
#3
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
I agree about the possible leak, but also check to be sure the spout
itself is not leaking. Many spouts have an adjustable sleeve in them to adjust for wall thickness and pipe stub length. That sleeve might be leaking, or maybe you just need some teflon tape on the stub pipe threads. I'd try the teflon tape and inspect the spout, and it's sleeve. If it still leaks, obtain another spout and test that one. If you still got a leak, you probably got a pipe leak. Another thing you might try is to put a cap on the end of the pipe and turn on the water. Then listen for leaking water. If it drips, you got a leak. If not, the spout itself is bad. If you are lucky, the rear of the tub wall is a closet, where you can make an access panel. Make it permanent. A 16" square of 1/4" plywood and 4 screws are all you need. I never understood why people put a permanent wall behind tub plumbing. Sooner or later, there will be a need to get to that piping. Mark ----------------------- On Thu, 27 Jul 2006 11:31:55 -0500, "Darrell Dorsey" wrote: Sounds like you may have a leak in the spout piping. When you install the spout there is then enough backpressure to force the water out the leaking spot. Without the spout, then isn't enough backpressure to force the leak. Do you have any access to the back side of the tub. Like in a closet or something. You would need to cut an opening. If its in a closet, you can just make a nice panel to cover the cut out. Darrell "CJ" wrote in message roups.com... If I connect the tub spout to the copper piping and run the water completely thru the spout; water drips to the underneath ceiling. If I disconnect the tub spout so only the copper piping shows, and then run the water completely thru the spout; no water drips from underneath. Does anyone know what this could be? |
#5
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
OK, good explanation..... I think you explained the problem.
I bet you got a bad seal at the diverter handle and it's running back thru the trim around the handle. I have seen that once. Assuming there is a shower head, there could also be a leak in the shower supply pipe and the spout is causing enough back pressure to cause either the shower supply pipe or the diverter to leak. I'd suspect the diverter first. You might just replace the parts in the diverter. (I assume you have a separate handle type). There is most likely a washer of some type and an O-ring or packing around the stem. That O-ring or packing is likely bad. It's worth the couple bucks to replace those parts and see if that does it. Those parts tend to degrade faster than the faucet ones from being dry most of the time. Mark On 27 Jul 2006 12:40:17 -0700, "CJ" wrote: I had bought a new spout and applied teflon tape on the pipe threads, and when I installed the spout, it gave the same result as the old spout. One question I have is could the diverter be taking the back-pressure when the water pressure is high and only going through the spout? I did notice water dripping from the diverter handle when the water pressure was high and only going through the spout. wrote: I agree about the possible leak, but also check to be sure the spout itself is not leaking. Many spouts have an adjustable sleeve in them to adjust for wall thickness and pipe stub length. That sleeve might be leaking, or maybe you just need some teflon tape on the stub pipe threads. I'd try the teflon tape and inspect the spout, and it's sleeve. If it still leaks, obtain another spout and test that one. If you still got a leak, you probably got a pipe leak. Another thing you might try is to put a cap on the end of the pipe and turn on the water. Then listen for leaking water. If it drips, you got a leak. If not, the spout itself is bad. If you are lucky, the rear of the tub wall is a closet, where you can make an access panel. Make it permanent. A 16" square of 1/4" plywood and 4 screws are all you need. I never understood why people put a permanent wall behind tub plumbing. Sooner or later, there will be a need to get to that piping. Mark ----------------------- On Thu, 27 Jul 2006 11:31:55 -0500, "Darrell Dorsey" wrote: Sounds like you may have a leak in the spout piping. When you install the spout there is then enough backpressure to force the water out the leaking spot. Without the spout, then isn't enough backpressure to force the leak. Do you have any access to the back side of the tub. Like in a closet or something. You would need to cut an opening. If its in a closet, you can just make a nice panel to cover the cut out. Darrell "CJ" wrote in message roups.com... If I connect the tub spout to the copper piping and run the water completely thru the spout; water drips to the underneath ceiling. If I disconnect the tub spout so only the copper piping shows, and then run the water completely thru the spout; no water drips from underneath. Does anyone know what this could be? |
#6
![]()
Posted to alt.home.repair
|
|||
|
|||
![]() |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Hot Water Recirculator Comfort Valve Inefficiencies Cost More Then An Outlet Install | Home Repair | |||
Salt content of softened water | Home Repair | |||
The #1 rated home water filter in America Aquasana AQ-4000 | Home Repair | |||
Detergents and cleaners FAQ | UK diy | |||
hot water recirculator, instant hot water but not a water heating unit, saves water, gas, time, money | Home Repair |