Default Ground outdoor MV security light?

Hello everyone;

I bought a 175W mercury vapor secuirty light and I want to install it next to my above ground pool. My plan is to buy a 4x4 16' treated lumber or use a 2" 20' metal fence post pipe (which I already have) to use as a pole; -4 feet into the ground (soil).

I plan to connect it to the GFCI outlet which my pump/filter is plugged into. The circuit is on a 20 amp breaker (12/2 UF) which runs from my garage's sub panel; underground about 40+ft. to the GFCI. Now i'm worried that if I install this light that high in the air; it might become a great lightning rod!!! Right? Especially if I use the metal pipe as the pole. What should I do (ground or no ground)? Also, I don't run the pump at night so these (light and motor) aren't going to be on at the same time. Thanks, Johnson
  #2   Report Post  
Posted to alt.home.repair
John Grabowski
 
Posts: n/a
Default Ground outdoor MV security light?


"EJohnson" wrote in message
...

Hello everyone;

I bought a 175W mercury vapor secuirty light and I want to install it
next to my above ground pool. My plan is to buy a 4x4 16' treated
lumber or use a 2" 20' metal fence post pipe (which I already have) to
use as a pole; -4 feet into the ground (soil).

I plan to connect it to the GFCI outlet which my pump/filter is plugged
into. The circuit is on a 20 amp breaker (12/2 UF) which runs from my
garage's sub panel; underground about 40+ft. to the GFCI. Now i'm
worried that if I install this light that high in the air; it might
become a great lightning rod!!! Right? Especially if I use the metal
pipe as the pole. What should I do (ground or no ground)? Also, I don't
run the pump at night so these (light and motor) aren't going to be on
at the same time. Thanks, Johnson


--
EJohnson


You can alleviate the lightning concern by driving a ground rod adjacent to
the pole and connect it with #8 or #6 copper wire.

Make sure that the light does not hang directly over the pool.

  #3   Report Post  
Posted to alt.home.repair
John Grabowski
 
Posts: n/a
Default Ground outdoor MV security light?


"EJohnson" wrote in message
...

Should I still use both #12 ground wire that is with the 12/2 UF cable
AND the #8 or #6 ground rod too OR just the #6 and ground rod? Infact;
this light is going to be about 14ft. in the air so it's not likely
someone would touch it. I decided to use the wood 4x4 post; Afraid that
the hot wire would get pinched inside the metal pipe and become
energized. Bad situation by a swimming pool!!! Johnson


--
EJohnson


Use both ground wires as they will each provide different functions. The
#12 will be effective in tripping the circuit breaker if there is a ground
fault. The #6 connected to the ground rod will enable lightning to go
directly to earth without affecting your home's wiring.

  #4   Report Post  
Posted to alt.home.repair
PipeDown
 
Posts: n/a
Default Ground outdoor MV security light?


"EJohnson" wrote in message
...

Hello everyone;

I bought a 175W mercury vapor secuirty light and I want to install it
next to my above ground pool. My plan is to buy a 4x4 16' treated
lumber or use a 2" 20' metal fence post pipe (which I already have) to
use as a pole; -4 feet into the ground (soil).

I plan to connect it to the GFCI outlet which my pump/filter is plugged
into. The circuit is on a 20 amp breaker (12/2 UF) which runs from my
garage's sub panel; underground about 40+ft. to the GFCI. Now i'm
worried that if I install this light that high in the air; it might
become a great lightning rod!!! Right? Especially if I use the metal
pipe as the pole. What should I do (ground or no ground)? Also, I don't
run the pump at night so these (light and motor) aren't going to be on
at the same time. Thanks, Johnson


--
EJohnson


12' is not all that high unless you are in the middle of a golf course. If
lightning is going to hit that spot, there is little you can do about it.
Directing the current into ground (via another ground wire aside from the
one to the GFCI) protects the structure but sidestrikes (to people and
bathers) from roots and underground pipes can still occur.

Naturally, you should NEVER use your pool when lightning is around anyway
even if it has not started raining.

Poolwater with all that chlorine is generally plenty conductive.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
External security light has failed Clive UK diy 8 February 20th 06 09:48 AM
electrical interruption Choreboy Home Repair 41 April 17th 05 10:14 PM
Inground spa light replac barry martin Home Repair 0 October 14th 04 12:30 AM
Inground spa light replacement question Neal Home Repair 2 October 4th 04 02:28 AM
Change a light bulb Usenet Style Stormin Mormon Home Repair 1 July 18th 04 11:03 AM


All times are GMT +1. The time now is 08:25 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"