Fibreglass Insulation for basement walls question
I am renovating my basement and the walls right now are 2 X 4 walls. I want
to insulate the walls and was told to use R20 which is 6 inches thick I believe. Now I do have the room for the insulation and the foundation wall. Here is my problem. I don't know if I should go with the 6 inch stuff or the less thicker stuff. The 6 inch stuffis barely touching the concrete wall. The foundation is dry and doesn;t leak. I was told that I need a few inches between the insulation and the concrete wall for maximum efficiency of th einsulation. Any comments??!!?? |
#2
Posted to alt.home.repair
|
|||
|
|||
Fibreglass Insulation for basement walls question
The description is confusing, where did the extra 2" of room come from
? Insulation IMO should be installed in such a way that it is not compressed at all; I don't see the need for the "extra few inches" gap. |
#3
Posted to alt.home.repair
|
|||
|
|||
Fibreglass Insulation for basement walls question
|
#4
Posted to alt.home.repair
|
|||
|
|||
Fibreglass Insulation for basement walls question
Any basement even visably dry may be to wet to close up resulting in
mold, get a moisture meter and test your walls after big rains. If dry you don`t want an air gap, I used 2" R 7.2" foamboard for R 14.4. on basement walls, much thinner than fiberglass, On damp areas it is all designed for easy removal and future repairs. Another consideration for foam is pipes brake , basements flood. |
#5
Posted to alt.home.repair
|
|||
|
|||
Fibreglass Insulation for basement walls question
The description is confusing, where did the extra 2" of room come from ? Insulation IMO should be installed in such a way that it is not compressed at all; I don't see the need for the "extra few inches" gap. Is your "IMO" anything other than a wild-assed guess, though? (A)What's the R-factor for 6" fiberglass in a 2x6 studwall? (B)What's the R-factor for 6" fiberglass stuffed into a 2x4 studwall? (C)What's the R-factor for 4" fiberglass in a 2x4 studwall? I suspect that you will find that ABC. In any case, OP would be better off spraying in Urethane foam. and not using fiberglass at all. Note to OP: If you're really sure that you won't get any groundwater wicking through the foundation wall, then you shouldn't need the airspace, but you should be really anal about the vapor barrier on the inside surface of the wall. If you're NOT sure, then I strongly recommend a closed-cell foam product against the wall. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
New insulation installed over existing - vapor barrier question | Home Repair | |||
Heating .. Insulation .. installation question | Home Repair | |||
Loft insulation question with a view to future conversion.... | UK diy | |||
Insulation question near lights | Home Repair | |||
Low voltage lights and loft insulation question | UK diy |