Default Solar hot air assist design needed.

I'm wanting to install a simple solar collector for heating air into my
shop, just as an assist - not full-out heating. Apologies in advance if
this isn't the right forum but couldn't find a NG that seems to fit. I know
that I saw a slew of these back in the 70's but I'll be hanged if I can come
up with one now. I was thinking of a flat, baffled collector which would
convect air from inside the shop, to the bottom chamber of the panel while
the top chamber heated up and convected the warm air into the shop. It
would seem logical that the baffle plate should be sheetmetal for quicker
heat-up. The window is only 20" wide so I guess the width of the collector
is predetermined (or maybe I can make it wider and neck it down to fit the
window - other funtional issues come to mind with that). The installation
was to angle the collector to match your latitude (+/-) and fit the top with
an extension appropriately angle to bring it into the shop, with diverters
to prevent the heated air from re-entering the collector. So, what's the
consensus of opinion? No fair asking the wife.


  #2   Report Post  
 
Posts: n/a
Default Solar hot air assist design needed.

Try alt.energy.homepower for such a NG.
J

  #3   Report Post  
m Ransley
 
Posts: n/a
Default Solar hot air assist design needed.

Alt.energy.homepower might help

  #4   Report Post  
Bob
 
Posts: n/a
Default Solar hot air assist design needed.


"C & M" wrote in message ...
I'm wanting to install a simple solar collector for heating air into my
shop, just as an assist - not full-out heating. Apologies in advance if
this isn't the right forum but couldn't find a NG that seems to fit. I know
that I saw a slew of these back in the 70's but I'll be hanged if I can come
up with one now. I was thinking of a flat, baffled collector which would
convect air from inside the shop, to the bottom chamber of the panel while
the top chamber heated up and convected the warm air into the shop. It
would seem logical that the baffle plate should be sheetmetal for quicker
heat-up. The window is only 20" wide so I guess the width of the collector
is predetermined (or maybe I can make it wider and neck it down to fit the
window - other funtional issues come to mind with that). The installation
was to angle the collector to match your latitude (+/-) and fit the top with
an extension appropriately angle to bring it into the shop, with diverters
to prevent the heated air from re-entering the collector. So, what's the
consensus of opinion? No fair asking the wife.


If this is to go into a window, why do you need a collector? Just let the sun come in the window.

Bob


  #5   Report Post  
SQLit
 
Posts: n/a
Default Solar hot air assist design needed.


"C & M" wrote in message
...
I'm wanting to install a simple solar collector for heating air into my
shop, just as an assist - not full-out heating. Apologies in advance if
this isn't the right forum but couldn't find a NG that seems to fit. I

know
that I saw a slew of these back in the 70's but I'll be hanged if I can

come
up with one now. I was thinking of a flat, baffled collector which would
convect air from inside the shop, to the bottom chamber of the panel while
the top chamber heated up and convected the warm air into the shop. It
would seem logical that the baffle plate should be sheetmetal for quicker
heat-up. The window is only 20" wide so I guess the width of the

collector
is predetermined (or maybe I can make it wider and neck it down to fit the
window - other funtional issues come to mind with that). The installation
was to angle the collector to match your latitude (+/-) and fit the top

with
an extension appropriately angle to bring it into the shop, with diverters
to prevent the heated air from re-entering the collector. So, what's the
consensus of opinion? No fair asking the wife.


A friend of mine sold these in the 70's in Iowa. Took one winter for him to
bail on the idea.
The reason you do not still see them is that they did not work all that
well. His worked well in the day time and turned into a radiator exhausting
the heat from his house at night.




  #6   Report Post  
MattMika
 
Posts: n/a
Default Solar hot air assist design needed.

C & M wrote:

I'm wanting to install a simple solar collector for heating air into my
shop, just as an assist - not full-out heating. Apologies in advance if
this isn't the right forum but couldn't find a NG that seems to fit. I
know that I saw a slew of these back in the 70's but I'll be hanged if I
can come up with one now. I was thinking of a flat, baffled collector
which would convect air from inside the shop, to the bottom chamber of the
panel while
the top chamber heated up and convected the warm air into the shop. It
would seem logical that the baffle plate should be sheetmetal for quicker
heat-up. The window is only 20" wide so I guess the width of the
collector is predetermined (or maybe I can make it wider and neck it down
to fit the
window - other funtional issues come to mind with that). The installation
was to angle the collector to match your latitude (+/-) and fit the top
with an extension appropriately angle to bring it into the shop, with
diverters
to prevent the heated air from re-entering the collector. So, what's the
consensus of opinion? No fair asking the wife.


Try www.builditsolar.com and click on projects. They have a few different
plans...

--
MattMika
  #7   Report Post  
 
Posts: n/a
Default Solar hot air assist design needed.

SQLit wrote:

"C & M" wants to:


install a simple solar collector for heating air into my shop...


Good idea.

I was thinking of a flat, baffled collector which would convect air from
inside the shop, to the bottom chamber of the panel while the top chamber
heated up and convected the warm air into the shop...


Sounds overly complex. All you need is some glazing over a dark south wall
with an air gap behind it and a hole at the bottom for shop air to enter
the gap and a hole at the top for solar-warmed air to move back up into
the shop during the day and a lightweight one-way plastic film damper over
the hole at the top (and/or bottom) to prevent reverse airflow at night.

The glazing could be a layer of 4-year greenhouse polyethylene film (5
cents/ft^2) or 20-year polycarbonate (about $1/ft^2) eg corrugated Sun Tuf
from Home Depot. The damper could be a dry cleaner bag, hinged at the top,
opening into the shop, with some hardware cloth over the hole to keep it
from flopping back outside through the hole at night. The glazing might be
6" from the south wall, or it might be a useful sunspace, eg an 8' radius
x 16' long quarter-cylinder with 5 $5 bows on 4' centers made from 2 12'
1x3s bent to an 8' radius with 1x3 spacer blocks on 2' centers screwed
between the 1x3s.

The window is only 20" wide so I guess the width of the collector is
predetermined (or maybe I can make it wider and neck it down to fit
the window...


Sure. The vent opening area might be 2-5% of the sunspace glazing area.

The installation was to angle the collector to match your latitude (+/-)


Vertical glazing works better for winter heating.

A friend of mine sold these in the 70's in Iowa... The reason you do not
still see them is that they did not work all that well.


Nonsense. They work fine. NREL says 480 Btu/ft^2 of sun falls on the ground
and 900 falls on a south wall on an average December day in Boston, with
an average 36 F daytime temp, so a $50 8'x16' sunspace like the one above
with 250 ft^2 of R1 glazing with 90% solar transmission might collect
0.9x8x16x(480+900) = 159K Btu of sun and lose 6h(70-36)250ft^2/R1 = 51K Btu,
for a net gain of 108K Btu, roughly the heat equivalent of a gallon of oil
or a therm of natural gas.

His worked well in the day time and turned into a radiator exhausting
the heat from his house at night.


The solar subsidies of the 70s brought forth a lot of incompetent
vendors. Sounds like he forgot the one-way plastic film dampers,
aka "the 7 cent solution" :-)

Nick

  #8   Report Post  
 
Posts: n/a
Default Solar hot air assist design needed.

One idea, not terribly complex, is he

http://www.jrwhipple.com/sr/solheater.html

Mark

  #9   Report Post  
C & M
 
Posts: n/a
Default Solar hot air assist design needed.


wrote in message
oups.com...
One idea, not terribly complex, is he

http://www.jrwhipple.com/sr/solheater.html

Mark


That's the one I remember. I'll have to sort thru all of the other ideas
too.
Thanks to all!!
C of C&M


  #10   Report Post  
DA
 
Posts: n/a
Default Solar hot air assist design needed.

C & M wrote:


I'm wanting to install a simple solar collector for heating air into my
shop, just as an assist - not full-out heating. Apologies in advance


Pick up the last issue of Home Power magazine. It has *exactly* what you
need: an article on building auxiliary assist solar air heater for a
barn/shop. With bill of materials and improvements list. I think you'll
get some ideas from it.

Cheers!
D.
-------------------------------------


##-----------------------------------------------##
Delivered via http://www.equity-loan.info/
Your home, its financing and everything about it
Web and RSS access to your favorite newsgroup -
alt.home.repair - 61142 messages and counting!
##-----------------------------------------------##


  #11   Report Post  
C & M
 
Posts: n/a
Default Solar hot air assist design needed.


"DA" wrote in message
...
C & M wrote:


I'm wanting to install a simple solar collector for heating air into my
shop, just as an assist - not full-out heating. Apologies in advance


Pick up the last issue of Home Power magazine. It has *exactly* what you
need: an article on building auxiliary assist solar air heater for a
barn/shop. With bill of materials and improvements list. I think you'll
get some ideas from it.

Cheers!
D.

WoooHoo thanks!

##-----------------------------------------------##


  #12   Report Post  
 
Posts: n/a
Default Solar hot air assist design needed.

In article ,
says...

SQLit wrote:

"C & M" wants to:


install a simple solar collector for heating air into my shop...


Good idea.

I was thinking of a flat, baffled collector which would convect air from
inside the shop, to the bottom chamber of the panel while the top chamber
heated up and convected the warm air into the shop...


Sounds overly complex. All you need is some glazing over a dark south wall
with an air gap behind it and a hole at the bottom for shop air to enter
the gap and a hole at the top for solar-warmed air to move back up into
the shop during the day and a lightweight one-way plastic film damper over
the hole at the top (and/or bottom) to prevent reverse airflow at night.

The glazing could be a layer of 4-year greenhouse polyethylene film (5
cents/ft^2) or 20-year polycarbonate (about $1/ft^2) eg corrugated Sun Tuf
from Home Depot. The damper could be a dry cleaner bag, hinged at the top,
opening into the shop, with some hardware cloth over the hole to keep it
from flopping back outside through the hole at night. The glazing might be
6" from the south wall, or it might be a useful sunspace, eg an 8' radius
x 16' long quarter-cylinder with 5 $5 bows on 4' centers made from 2 12'
1x3s bent to an 8' radius with 1x3 spacer blocks on 2' centers screwed
between the 1x3s.

The window is only 20" wide so I guess the width of the collector is
predetermined (or maybe I can make it wider and neck it down to fit
the window...


Sure. The vent opening area might be 2-5% of the sunspace glazing area.

The installation was to angle the collector to match your latitude (+/-)


Vertical glazing works better for winter heating.

A friend of mine sold these in the 70's in Iowa... The reason you do not
still see them is that they did not work all that well.


Nonsense. They work fine. NREL says 480 Btu/ft^2 of sun falls on the ground
and 900 falls on a south wall on an average December day in Boston, with
an average 36 F daytime temp, so a $50 8'x16' sunspace like the one above
with 250 ft^2 of R1 glazing with 90% solar transmission might collect
0.9x8x16x(480+900) = 159K Btu of sun and lose 6h(70-36)250ft^2/R1 = 51K Btu,
for a net gain of 108K Btu, roughly the heat equivalent of a gallon of oil
or a therm of natural gas.

His worked well in the day time and turned into a radiator exhausting
the heat from his house at night.


The solar subsidies of the 70s brought forth a lot of incompetent
vendors. Sounds like he forgot the one-way plastic film dampers,
aka "the 7 cent solution" :-)

Nick