Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Wayne Whitney
 
Posts: n/a
Default Why no condensing tankless gas water heaters?

Hello,

I'm shopping for a gas water heater, and I'd like to get the most
efficient model possible. As I understand it, when comparing
efficiencies, the energy factor is the only important number. The
highest energy factor that I can find is 0.85, from either a tankless
water heater, or a condensing tank water heater. See, for example,
http://www.oregon.gov/ENERGY/CONS/RES/tax/appheat.shtml.

Now all the tankless units I'm aware of are non-condensing units, so
their thermal efficiency is at most 85%. I guess a tankless unit has
no standby losses, so the energy factor is equal to the thermal
efficiency, hence the 0.85 maximum energy factor.

I'm a bit surprised that the condensing tank water heaters also have a
maximum energy factor of 0.85, since their thermal efficiency can be
up to 95%. I guess a 0.05 loss in energy factor is attributable to
the standby losses through the tank, which is why electric water
heaters have a maximum energy factor of 0.95. This suggests that the
remaining 0.05 loss in energy factor is due to standby losses through
the condensing flue?

Is this analysis above correct? If so, why doesn't anyone make a
condensing tankless gas water heater? I would think you could use the
vent gasses to preheat the incoming cold water, thereby condensing the
vent gasses. It ought to allow for an energy factor of 0.90 to 0.95.

Thanks, Wayne
  #2   Report Post  
Wayne Whitney
 
Posts: n/a
Default Why no condensing tankless gas water heaters?

On 2005-10-06, Wayne Whitney wrote:

If so, why doesn't anyone make a condensing tankless gas water
heater?


To followup up on myself, apparently there is at least one condensing
tankless gas water heater, the Takagi T-H1. Unfortunately, it seems
to cost 2.5 times as much as a comparably sized non-condensing unit.
That's a big price increased to go from a 0.85 Energy Factor to a 0.94
Energy Factor. I'm also surprised that it still requires a Category
III (sealed stainless steel) vent.

Cheers, Wayne
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
AquaTherm Furnace - No Hot Water Issue David Home Repair 11 January 25th 18 08:44 PM
Rennai Tankless Water Heaters Harry Everhart Home Repair 20 March 10th 05 01:45 PM
Tankless Hot Water Heaters Questions Robert11 Home Repair 22 November 18th 04 10:21 PM
Hot water recirculation [email protected] Home Repair 18 August 9th 04 05:32 AM
Thankless or Tankless hot water heaters [email protected] Home Repair 6 January 29th 04 03:01 AM


All times are GMT +1. The time now is 06:51 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"