I purchased a energy efficient ceiling fixture to replace a kitchen
light. (It is not recessed). The directions warn that it should not be
connected to house wire not capable of withstanding x degrees Celsius.
(I think x is 70 or 90). Since my house was built in the 1960s, I
don't have any idea how hot max the wire is designed to get, but IIRC
most wire of that era was designed for 60 C.

So what is the proper way to wire a new fixture? I'm surprised the
wire temperature max rating is such an issue, the enegy efficient
florescent lighting seems to be much cooler than incandescent.

Thanks!


  #2   Report Post  
SQLit
 
Posts: n/a
Default


"Jim Taylor" wrote in message
...
I purchased a energy efficient ceiling fixture to replace a kitchen
light. (It is not recessed). The directions warn that it should not be
connected to house wire not capable of withstanding x degrees Celsius.
(I think x is 70 or 90). Since my house was built in the 1960s, I
don't have any idea how hot max the wire is designed to get, but IIRC
most wire of that era was designed for 60 C.

So what is the proper way to wire a new fixture? I'm surprised the
wire temperature max rating is such an issue, the enegy efficient
florescent lighting seems to be much cooler than incandescent.

Thanks!


As far as I know your correct about the residential wiring of the era.

My guess is that the manufacture said 90 c. Which is what the newer
residential wire is rated for, I believe.
You could always pig tail a piece of thhn or thwn to the home wiring and
then connect to the fixture.


  #3   Report Post  
RBM
 
Posts: n/a
Default

I think it's an easy method for the manufacturer to exempt themselves from
liability in case of fire. Most houses don't have 90 degree wire and I doubt
most people are going to rewire the outlet box just to accommodate fixtures
with that listing. Having said that, there are however fixtures made that do
generate a lot of heat on the outlet box they are attached to and the wire
supplying those fixtures should be of 90 degree rating






...
I purchased a energy efficient ceiling fixture to replace a kitchen
light. (It is not recessed). The directions warn that it should not be
connected to house wire not capable of withstanding x degrees Celsius.
(I think x is 70 or 90). Since my house was built in the 1960s, I
don't have any idea how hot max the wire is designed to get, but IIRC
most wire of that era was designed for 60 C.

So what is the proper way to wire a new fixture? I'm surprised the
wire temperature max rating is such an issue, the enegy efficient
florescent lighting seems to be much cooler than incandescent.

Thanks!




  #4   Report Post  
Bill
 
Posts: n/a
Default

The light itself is cooler, but florescent lights have a "ballast" which
can get to be quite hot. (At least with commercial fixtures.)

Heat travels up, also heat can get trapped with insulation, in the metal
box holding the electrical wires, etc.

I've seen insulation from old wires just crumble when I removed a wall
fixture in a bathroom. And that was not even a ceiling fixture. Some of the
insulation had fallen off by itself. Note that this fixture was part of a
metal medicine cabinet, so could have been a shock hazard as there was no
grounding!

The heat from the fixture wrecked the insulation on the old wiring.

I would replace the wiring whether it needs it or not, since it may have
been damaged by the previous fixture. The new stuff is *so* much safer than
the old (grounding, high heat insulation, etc.)!



"Jim Taylor" wrote in message
I purchased a energy efficient ceiling fixture to replace a kitchen
light. (It is not recessed). The directions warn that it should not be
connected to house wire not capable of withstanding x degrees Celsius.
(I think x is 70 or 90). Since my house was built in the 1960s, I
don't have any idea how hot max the wire is designed to get, but IIRC
most wire of that era was designed for 60 C.

So what is the proper way to wire a new fixture? I'm surprised the
wire temperature max rating is such an issue, the enegy efficient
florescent lighting seems to be much cooler than incandescent.

Thanks!




  #5   Report Post  
Bud
 
Posts: n/a
Default

Bill wrote:
I've seen insulation from old wires just crumble when I removed a wall
fixture in a bathroom. And that was not even a ceiling fixture. Some of the
insulation had fallen off by itself. Note that this fixture was part of a
metal medicine cabinet, so could have been a shock hazard as there was no
grounding!

I've run acoss the same thing - you move the wire and the insulation
still remianing cracks off. Old circline flourescent fixtures could
cause this.

The heat from the fixture wrecked the insulation on the old wiring.

I would replace the wiring whether it needs it or not, since it may have
been damaged by the previous fixture. The new stuff is *so* much safer than
the old (grounding, high heat insulation, etc.)!

The solution? Get a fixture that is rated for 60°C supply wiring. It is
common for fixtures to have insulation built into the top to limit heat
problems. I'm not impressed with the fixture manufacturer. Seems obvious
a lot of these will be installed with 60°C wiring.

Bud--


  #6   Report Post  
HorneTD
 
Posts: n/a
Default

SQLit wrote:
"Jim Taylor" wrote in message
...

I purchased a energy efficient ceiling fixture to replace a kitchen
light. (It is not recessed). The directions warn that it should not be
connected to house wire not capable of withstanding x degrees Celsius.
(I think x is 70 or 90). Since my house was built in the 1960s, I
don't have any idea how hot max the wire is designed to get, but IIRC
most wire of that era was designed for 60 C.

So what is the proper way to wire a new fixture? I'm surprised the
wire temperature max rating is such an issue, the enegy efficient
florescent lighting seems to be much cooler than incandescent.

Thanks!



As far as I know your correct about the residential wiring of the era.

My guess is that the manufacture said 90 c. Which is what the newer
residential wire is rated for, I believe.
You could always pig tail a piece of thhn or thwn to the home wiring and
then connect to the fixture.



No you can't. The lower rated 60C rated conductors need to be far
enough away to be unaffected by the heat the fixture gives off. If the
space above is accessible you move the old cables into a Jbox and run a
cable from that Jbox to the fixture box. If the old cables are not
relocated the heat from the fixture will cook the insulation right off
the wires and they will fault out. Because the process is gradual it
has a higher likelihood of arcing faults that can kindle a fire.
--
Tom Horne

"This alternating current stuff is just a fad. It is much too dangerous
for general use." Thomas Alva Edison


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Light Bulb Phil UK diy 18 March 27th 05 05:50 PM
Hot light fixture spheres BARRY MARTIN Home Repair 0 February 22nd 05 02:43 PM
Old house, Ceiling Light Fixture Died, No Change After New Switch ASE Home Repair 3 February 7th 05 01:57 AM
Help wiring double light switch Mike UK diy 4 December 10th 04 11:12 PM
Light Socket Wiring Query L Reid UK diy 6 December 11th 03 10:36 AM


All times are GMT +1. The time now is 08:48 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"