Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
mc
 
Posts: n/a
Default Tek 422 scope "whine"

I have a Tektronixs 422 scope that I've had for years. I'm getting ready to
put it up on eBay - but is has a "whine" when it's on. The traces are fine,
everything works - but I want to be honest and not have any buyer trouble.

Is this normal in an older scope? What is it, can it be fixed? It's a
really nice older "vintage" scope - just never use it and need to find a
good home for it.

please email me at since my newsreader service
never seems to keep any old messeges.


(remove the *nospam*)




  #2   Report Post  
tekman
 
Posts: n/a
Default


mc wrote:
I have a Tektronixs 422 scope that I've had for years. I'm getting

ready to
put it up on eBay - but is has a "whine" when it's on. The traces

are fine,
everything works - but I want to be honest and not have any buyer

trouble.

Is this normal in an older scope?


No, not normal. But may happen.

What is it, can it be fixed? It's a
really nice older "vintage" scope - just never use it and need to

find a
good home for it.


Cause forthe whine may be :
1. old caps (dried out electrolytics which lost part of their capacity.

2. Loose or broken ferrite core on the inverter transfomer.
3. An overload on one voltage -- but very unlikely in your case bec.
you mention: "all other behaviour as normal, trace okay, etc."

please email me at since my newsreader

service
never seems to keep any old messeges.


No email -- you have to look on the NG-- the reason for a newsgroup
that many people can read the answer and participate from them.

With email, that's not possible.

hth,
Andreas

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Need help fixing a Tek scope Juerg Electronics Repair 20 April 14th 05 12:37 AM
Problem with Tektronix scope 7313 Jim Yanik Electronics Repair 4 August 5th 04 12:37 PM
Tektronix 466 Scope Problem Chris Electronics Repair 13 December 24th 03 03:50 PM
BK Precision 1522 scope: bad input section, no trace Ben Byer Electronics Repair 3 September 22nd 03 10:29 PM
opinions on buying a scope tempus fugit Electronics Repair 18 July 31st 03 02:29 PM


All times are GMT +1. The time now is 08:33 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"