Home |
Search |
Today's Posts |
![]() |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
![]() |
|||
|
|||
![]()
This is the 2nd Ample Audio A 1100 DX car amp
I've gotten in for service this month with a "ghostly" protect problem. Get this; Amp instantly goes into protection upon power up. Okay, that's not unusual but, NO shorted mosfets in power supply or Audio section.( I even pulled the rectifiers out of circuit to isolate the PS) No pri/sec shorts in Xformer. No leaky or shorted "totum pole" trans. Swapped out the TL494 pulse wave chip. (checked all transistors in PS) The PS does try to gernerate square waves, I can see them appear briefly at the gates of the PS mosfets and at the secondary of Xformer. Admittedly, I am NOT a car amp Guru, but I have repaired enough of them to know my way around in there and I'm scratching my head. Hopfully, someone out there has seen this or has more ideas. TIA, humbley, RIck |
#2
![]() |
|||
|
|||
![]()
Either the internal power supply, or inverter (if there is one), has a
short, or one of the stages, especialy the output stage, is pulling too much current. The only way to find this, is to isolate the various stages in the set, and see which one is causing the fault. You will most likely have to cut a few traces to do this. Jerry G. ====== |
#3
![]() |
|||
|
|||
![]() "Jerry G." wrote in message ups.com... Either the internal power supply, or inverter (if there is one), has a short, or one of the stages, especialy the output stage, is pulling too much current. The only way to find this, is to isolate the various stages in the set, and see which one is causing the fault. You will most likely have to cut a few traces to do this. Sounds like he's already isolated it and it's still shutting down so this isn't particularly helpful. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
RCA EGA330s Audio Problem | Electronics Repair | |||
Signature 2000 (Zenith) Audio problems | Electronics Repair | |||
Magnavox TV model RS4254WA02, Ch. 19C506 no audio (repost) | Electronics Repair | |||
Toshiba TV mod. CF32C50, Ch. TAC9323 audio problems | Electronics Repair | |||
Sound: "fixing"/processing audio channel/s | Electronics Repair |