Hello everybody:

I am adjusting the LO hardware of my 2754P and there are some things that I
can not find or undestand:

After pressing shift 0 , loops calibration, overall system option the first
message is:

Connect a DVM on TP1058...etc (no problem )
(the meter shows 17mV)

Adjust frequency control
for a reading of 0.000 +/- 2mV

(problem WHICH FREQUENCY CONTROL?? OR POTENTIOMETER OR RESISTOR???)
The freuquency control board???


2.Connect a DVM on oint B of the controlled oscillator board and ground..
WHERE THE HECK IS POINT B AND WHERE IS THE CONTROLLED OSCILLATOR BOARD???

Thank you your help


  #2   Report Post  
Henry Kolesnik
 
Posts: n/a
Default

there's a Tek group on Yahoo & SA are discussed.
http://groups.yahoo.com/group/TekScopes/

--

73
Hank WD5JFR
"rfgelitronics" wrote in message
m...
Hello everybody:

I am adjusting the LO hardware of my 2754P and there are some things that
I can not find or undestand:

After pressing shift 0 , loops calibration, overall system option the
first message is:

Connect a DVM on TP1058...etc (no problem )
(the meter shows 17mV)

Adjust frequency control
for a reading of 0.000 +/- 2mV

(problem WHICH FREQUENCY CONTROL?? OR POTENTIOMETER OR RESISTOR???)
The freuquency control board???


2.Connect a DVM on oint B of the controlled oscillator board and ground..
WHERE THE HECK IS POINT B AND WHERE IS THE CONTROLLED OSCILLATOR BOARD???

Thank you your help



  #3   Report Post  
rfgelitronics
 
Posts: n/a
Default

This is an spectrum analyzer, but I will give it a try..

Thank you

"Henry Kolesnik" wrote in message
om...
there's a Tek group on Yahoo & SA are discussed.
http://groups.yahoo.com/group/TekScopes/

--

73
Hank WD5JFR
"rfgelitronics" wrote in message
m...
Hello everybody:

I am adjusting the LO hardware of my 2754P and there are some things that
I can not find or undestand:

After pressing shift 0 , loops calibration, overall system option the
first message is:

Connect a DVM on TP1058...etc (no problem )
(the meter shows 17mV)

Adjust frequency control
for a reading of 0.000 +/- 2mV

(problem WHICH FREQUENCY CONTROL?? OR POTENTIOMETER OR RESISTOR???)
The freuquency control board???


2.Connect a DVM on oint B of the controlled oscillator board and ground..
WHERE THE HECK IS POINT B AND WHERE IS THE CONTROLLED OSCILLATOR BOARD???

Thank you your help





Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
ROUTER Height adjustment Richard L. Woodworking 3 September 10th 04 04:08 PM
On lateral adjustment, Bailey planes Australopithecus scobis Woodworking 11 September 9th 04 10:16 PM
Plunge or non-plunge router better under table? LRod Woodworking 31 June 28th 04 10:23 PM
Hitachi Hi8 camcorder tracking adjustment marco Electronics Repair 3 January 2nd 04 05:04 AM
imac monitor adjustment: how to change factory settings? Andy Cuffe Electronics Repair 0 December 11th 03 05:10 PM