Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Larry B
 
Posts: n/a
Default Venerable Amana RR-10 Microwave

We love our RR-10 and are the original owners (since 1979). Chromed out
with stainless interior and digital touchpad. I do have a service manual but
it does not go into detail on the digital module. The digital module in this
particular model was made by Essex.

Last weekend, someone used it (not personally witnessed) and the digital
module (Touchmatic II) went dead. I don't know what mortal code they entered
on the touchpad but it is truly dead. I have a rusty old RR-10 in the garage
for parts. So, I replaced the tube thermal cutout switch (which was open)
and the digital module. The rusty digital module works great but has a poor
Wife Acceptance Factor. Unfortunately, the original module is still dead. As
a further clue, when the the connector plug for the module is plugged in,
the buzzer should chirp. The original doesn't even chirp.

I took it apart and found a cap that had caused the underside of the PC
board to turn color so I replaced it. I also cleaned to the contacts on an
unenclosed relay, too. Still dead. Since a new digital module is $170 I was
hoping to get some hints as to what would be the most likely part(s) at
fault. Since whatever happened took out the thermal cutout sw, I thought
there may be some kind of deductive logic that could be applied here.

Thanks for any and all insights,

Lar


  #2   Report Post  
**THE-RFI-EMI-GUY**
 
Posts: n/a
Default

First, check to see if there is a rectifier diode shorted which may have
caused the capacitor to burst. Next if the capacitor caused the board to
change color then you have electrolyte all over the PC board causing
current leakage. Try cleaning with strong alcohol, dry it and then check
for corroded solder connections. If it still won't work, its likely
trashed.

Larry B wrote:

We love our RR-10 and are the original owners (since 1979). Chromed out
with stainless interior and digital touchpad. I do have a service manual but
it does not go into detail on the digital module. The digital module in this
particular model was made by Essex.

Last weekend, someone used it (not personally witnessed) and the digital
module (Touchmatic II) went dead. I don't know what mortal code they entered
on the touchpad but it is truly dead. I have a rusty old RR-10 in the garage
for parts. So, I replaced the tube thermal cutout switch (which was open)
and the digital module. The rusty digital module works great but has a poor
Wife Acceptance Factor. Unfortunately, the original module is still dead. As
a further clue, when the the connector plug for the module is plugged in,
the buzzer should chirp. The original doesn't even chirp.

I took it apart and found a cap that had caused the underside of the PC
board to turn color so I replaced it. I also cleaned to the contacts on an
unenclosed relay, too. Still dead. Since a new digital module is $170 I was
hoping to get some hints as to what would be the most likely part(s) at
fault. Since whatever happened took out the thermal cutout sw, I thought
there may be some kind of deductive logic that could be applied here.

Thanks for any and all insights,

Lar





--
Joe Leikhim K4SAT
"The RFI-EMI-GUY"

The Lost Deep Thoughts By: Jack Handey
Before a mad scientist goes mad, there's probably a time
when he's only partially mad. And this is the time when he's
going to throw his best parties.
  #3   Report Post  
Andy Cuffe
 
Posts: n/a
Default

On Thu, 04 Nov 2004 16:02:07 GMT, "Larry B"
wrote:

Last weekend, someone used it (not personally witnessed) and the digital
module (Touchmatic II) went dead. I don't know what mortal code they entered
on the touchpad but it is truly dead. I have a rusty old RR-10 in the garage
for parts. So, I replaced the tube thermal cutout switch (which was open)
and the digital module. The rusty digital module works great but has a poor
Wife Acceptance Factor. Unfortunately, the original module is still dead. As
a further clue, when the the connector plug for the module is plugged in,
the buzzer should chirp. The original doesn't even chirp.




Why don't you swap the good electronics onto the good chrome? The
glass touch panel and all the electronics come off as a single unit.
Andy Cuffe

  #4   Report Post  
Larry B
 
Posts: n/a
Default


"Andy Cuffe" wrote in message
...
On Thu, 04 Nov 2004 16:02:07 GMT, "Larry B"
wrote:

Last weekend, someone used it (not personally witnessed) and the digital
module (Touchmatic II) went dead. I don't know what mortal code they

entered
on the touchpad but it is truly dead. I have a rusty old RR-10 in the

garage
for parts. So, I replaced the tube thermal cutout switch (which was

open)
and the digital module. The rusty digital module works great but has a

poor
Wife Acceptance Factor. Unfortunately, the original module is still dead.

As
a further clue, when the the connector plug for the module is plugged in,
the buzzer should chirp. The original doesn't even chirp.




Why don't you swap the good electronics onto the good chrome? The
glass touch panel and all the electronics come off as a single unit.
Andy Cuffe


I was hoping to do just that except that the second unit is actually an
RR-10A. Everything interfaces the same but the module is a whole different
animal inside. Same basic individual parts but the layout, boards, etc are
all different. The touchpad is similar ("orangier" pads), mounting holes,
9-pin connector and switches are the same but it ends there. Thanks for your
thoughts.

Lar


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Kenmore microwave acting intermittently Beanie Electronics Repair 7 April 6th 08 07:58 PM
Samsung Microwave & GE Microwave oven Soyrunner Electronics Repair 5 March 15th 05 01:46 PM
The merits of microwave seasoning Ron Headon Woodturning 9 April 15th 04 04:49 PM
Sparking vegetables in microwave Shawn P. Good Home Repair 4 January 5th 04 12:18 PM


All times are GMT +1. The time now is 04:32 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"