Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Mistress
 
Posts: n/a
Default Sencore SC61 Waveform Analyzer - Dim display

I've had this thing for ages but have used it only rarely because the
display is so dim.

As I recall, I went through the circuitry a long while ago and found no
abnormal readings; leading me to suspect the CRT was the culprit.

A call to Sencore today lists the price of a new tube (18G28) at $198.
Ouch!
Does anyone have any fixit tips for this problem on an SC61.
Has anyone had success using an CRT rejuvinator on an 18G28?

Other suggestions?

Thank you.
  #2   Report Post  
Ray L. Volts
 
Posts: n/a
Default Sencore SC61 Waveform Analyzer - Dim display

You're lucky to get a knob for under $198 from Sencore.
I haven't hooked up my CRT restorer to this particular tube, so I can't say
how effective -- or possible -- it may be. But I do have the schematics in
case anyone has lost theirs or never had any in the first place. I'll be
glad to look up part values or voltages/waveforms, etc...


"Mistress" wrote in message
. ..
I've had this thing for ages but have used it only rarely because the
display is so dim.

As I recall, I went through the circuitry a long while ago and found no
abnormal readings; leading me to suspect the CRT was the culprit.

A call to Sencore today lists the price of a new tube (18G28) at $198.
Ouch!
Does anyone have any fixit tips for this problem on an SC61.
Has anyone had success using an CRT rejuvinator on an 18G28?

Other suggestions?

Thank you.



  #3   Report Post  
Bob Urz
 
Posts: n/a
Default Sencore SC61 Waveform Analyzer - Dim display



Mistress wrote:
I've had this thing for ages but have used it only rarely because the
display is so dim.

As I recall, I went through the circuitry a long while ago and found no
abnormal readings; leading me to suspect the CRT was the culprit.

A call to Sencore today lists the price of a new tube (18G28) at $198.
Ouch!
Does anyone have any fixit tips for this problem on an SC61.
Has anyone had success using an CRT rejuvinator on an 18G28?

Other suggestions?

Thank you.


Brightener on the CRT filaments maybe?

Bob



-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 100,000 Newsgroups - 19 Different Servers! =-----
  #4   Report Post  
George
 
Posts: n/a
Default Sencore SC61 Waveform Analyzer - Dim display

Mistress wrote in message ...
I've had this thing for ages but have used it only rarely because the
display is so dim.

As I recall, I went through the circuitry a long while ago and found no
abnormal readings; leading me to suspect the CRT was the culprit.

A call to Sencore today lists the price of a new tube (18G28) at $198.
Ouch!
Does anyone have any fixit tips for this problem on an SC61.
Has anyone had success using an CRT rejuvinator on an 18G28?

Other suggestions?

Thank you.


I rejuvinated the crt in my SC61 about 6 years ago and has worked fine
with a bright trace, i used a CR 70 sencore to rejuvate the crt
George Kirk
  #6   Report Post  
George
 
Posts: n/a
Default Sencore SC61 Waveform Analyzer - Dim display

Hello
I can't find the setup information for a 18G28.
If i remember i used the universal adaptor,
useing the crt schematic for proper connections.
If you don't have a schematic i can send you the
CRT elements and base connections.
Best regards
George Kirk
Time Antique Radio Restorations
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Three phase analyzer - meter. Martin H. Eastburn Metalworking 1 March 2nd 04 05:06 PM
Display has no hard wire connections. Denny B Electronics Repair 1 December 24th 03 06:33 PM
Siemens Gigaset 2420 Display problem Michael Drum Electronics Repair 2 November 7th 03 06:00 AM
sencore tv and video analyzer FS 1234 Electronics Repair 1 July 15th 03 11:41 AM


All times are GMT +1. The time now is 09:56 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us