Posted to sci.electronics.repair
|
|||
|
|||
![]()
On Sunday, 14 October 2018 02:04:13 UTC+1, Bob Engelhardt wrote:
On 9/8/2018 12:27 PM, Bob Engelhardt wrote: With a small bit in a Dremel I excavated behind the segment, down to its connecting wire.Â* There was no continuity from that wire to other segments!Â* Then I noticed what had been staring me in the face all along - the connecting wire exposed and broken: https://imgur.com/a/jhIcgqf Its connection to the segment also came loose, so I soldered in a jumper: https://imgur.com/a/yiBcCit It surprised me that the original connecting wire was steel.Â* I don't know why steel would be used, but it made soldering difficult. With it "fixed", it still sparked like crazy! It took a while, but I finally found a transformer that I could re-purpose as a growler. With that I discovered that the armature had shorted windings. Sigh. I took it as an opportunity to do something new: rewind an armature. There's a number of YouTube videos showing it and it doesn't seem too hard. First, I needed the parameters: size of wire, number of turns in each winding, and the connections of the windings to the commutator segments. It was easy on the videos - you just unwind the old and record the parameters. Not so on mine - the windings were potted with epoxy. With some careful destruction I got some of it unpotted, but not the connections to the commutator. So I trashed it. Part of the commutator connections problem was that there were jumpers from the commutator to the windings. Most (?) armatures have their windings loop around a lug on a commutator segment and continue. I.e., each lug is the start point of one winding and the end point of another. On mine there were 2 commutator segments per rotor slot; the jumper on one connected to a winding wire, but the jumper on the other connected to _2_ winding wires! How could there be 3 connections per slot? Bizarrely asymmetrical. I'm disappointed that it wasn't more doable. motors with partial short can be run in series with a 3kW heater - but not now. NT |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
OT more questions about armature | Metalworking | |||
OT? armature question (rotary inverter) | Metalworking | |||
Router Armature removal...Old Router | Woodworking | |||
Armature winding lathes | Metalworking | |||
Hotpoint WM64 armature | UK diy |