Hi, I would like to enquire if anyone can give me some advice about a repair
I did for a friend recently. The TV was a Philips 14PV182/05, which had a tripping powersupply. I tested most of the electrolytics with my ESR meter, and supprisingly they all read good. I tested the HOT - good, but the set worked with it removed. (Sound + VCR) I isolated all the secondary supplies derrived from the LOPT, but the set still tripped (HOT in place). So I presumed a faulty LOPT. This was confirmed by rudimentary ring testing on my oscilloscope. I replaced the LOPT with an HR equivilant, and the TV now appears to be working fine. My question is, weather I should be looking for an underlying cause for the original LOPT to fail. I did notice that there was some high frequency sound coming from the TV (Audible with the TV volume turned right down, and the cover off) - after I replaced the LOPT. This makes me wounder if everything is A-Ok, but I'm aware that transformers / capacitors can sometimes make some noise when running normally. Do LOPTs just fail on their own, or are they usually 'caused' to fail by another part? I've seen a cople of references to similar symptoms in this TV (PSU tripping) being fixed by just replacing the LOPT. Please note that I don't do this for a living or anything, I'm an electronic engineering student, and only have a few years worth of experience fixing the odd monitor / TV / SMPS etc. My theoretical knowledge isn't too bad (I think), but I lack the experience of someone who comes across these faults day after day. Thanks for you help Peter Clifton |
#2
|
|||
|
|||
Philips TV Repaired with LOPT -> Causes?
Peter Clifton schreef/a écrit/wrote in/dans/in
le/on/op 16/02/2004 : So I presumed a faulty LOPT. This was confirmed by rudimentary ring testing on my oscilloscope. Do LOPTs just fail on their own, or are they usually 'caused' to fail by another part? They fail on their own, Peter. Especially in those sets. We replace a few every week. The quality of those transformer has dropped dramaticaly. Sometimes the line output transistor has to be replaced as well and a little blue capacity, close to that transistor. Greetz, -- Alain Beguin http://home.tiscali.be/a.beguin mailto: http://cerbermail.com/?XiEiqwImaa MesNews Reader: http://www.zoo-logique.org/mesnews/index-gb.php |
#3
|
|||
|
|||
Philips TV Repaired with LOPT -> Causes?
Thanks for that - it makes me feel better about the job I did.
Presumably, if the cap or the HOT need replacing then it would show some visible sign of it when I powered the set up again. (I hope anyway) My friend has her TV back now, but if anyone thinks there is still cause to be concerned or investigate further, I could ask to look at it again. I love to repair things (and hence work for free - I wouldn't claim to have a high enough competence or give a high enough success rate to charge like a pro), but I can see why repairing televisions is becoming uneconomical nowadays. For a little more than the cost of parts and labour, people can simply buy a new TV which may (or may not perhaps) have more lifetime in it than a repaired 6yr old set. The new LOPT was about £20, and a new set was only £100. Once you add in labour, its getting to be a close call. Many thanks for your advice Peter "Alain Beguin" wrote in message ... Peter Clifton schreef/a écrit/wrote in/dans/in le/on/op 16/02/2004 : So I presumed a faulty LOPT. This was confirmed by rudimentary ring testing on my oscilloscope. Do LOPTs just fail on their own, or are they usually 'caused' to fail by another part? They fail on their own, Peter. Especially in those sets. We replace a few every week. The quality of those transformer has dropped dramaticaly. Sometimes the line output transistor has to be replaced as well and a little blue capacity, close to that transistor. Greetz, -- Alain Beguin http://home.tiscali.be/a.beguin mailto: http://cerbermail.com/?XiEiqwImaa MesNews Reader: http://www.zoo-logique.org/mesnews/index-gb.php |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Philips CDM-9 laser source | Electronics Repair | |||
Philips 7P6051 chassis PTV780 H. V. Splitter Needed! | Electronics Repair | |||
Philips car radio RC 459 RDS schematics | Electronics Repair | |||
Philips 36PT41B1 | Electronics Repair |