On Sun, 21 Feb 2016 13:36:49 -0000 (UTC), Cursitor Doom
wrote: snip In one of your pictures there are a couple of diodes that look messed up (V1809 and V1811) near the bridge. They are supposed to be BY208-1000 (1000v rectifiers), I can see "40" on one, maybe 1N4007? I like your thinking! But no, the one nearest the bridge is a BY208-1000 alright, the other one to the side of it is a BY134. They both tested fine out of circuit. The BY134 is a lower frequency part with 2uS recovery time and is probably unsuited to replacement of BY208-1000 in any of the snubber or conversion positions indicated on the schematic primary. It should be soft recovery, medium speed (200-600nS) avalanche-rated part with a minimum 800Vprv. I'd avoid the use of anything advertised as 'ultrafast' (ie UF4007), as this circuit may need a modest recovery time in order to reduce power loss and EMI, but they could be used temporarily in troubleshooting. RL |