On 2/21/2016 9:34 AM, Cursitor Doom wrote:
On Sat, 20 Feb 2016 15:45:34 -0500, JC wrote:

Have you posted this before on another thread related to this? Either you
have or it's deja vu. Sorry if you did, I didn't note it properly.

I managed to find a PM3264 PSU to try out.

Unloaded it squeals as expected so I tried a makeshift load with what I
had lying around, 6 x 470R 5Watt w/w resistors.

You can pull one of the connectors out of the scope for a connection.
(See photos)


Yeah, those Stocko connectors. On another Philips manual I have for a
different scope, they actually publish the proper values for a dummy load
which would be really helpful to have on the current problem I face.

Just for fun (and I'm running this off an isolation transformer), pull
V1812 and scope T2 with T1 as probe ground. you should see a nice drive
waveform for a few seconds and you can check the frequency is 20KHz.


Not sure why you say pull V1812, but here's the waveform I got between
those two points when I did this test a few weeks ago:

https://www.flickr.com/photos/128859...n/photostream/

But then it goes downhill. Here's V1812's C/E junction:

https://www.flickr.com/photos/128859...n/photostream/

And the B/E junction of the main chopper transistor:

https://www.flickr.com/photos/128859...n/photostream/

Not surprising it doesn't work properly with control voltages like that!!!


Pulling V1812 lets you see the clean output from the driver chip without
all the crap feedback from the transformers. Your frequency looks good.

I got the same crap and ringing/distortion on my PSU without a load. Put
a load on it. switchers don't work off load.


 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Returning to that Scope SMPS Problem... Cursitor Doom[_4_] Electronics Repair 21 February 27th 16 10:19 PM
'scope smps update Cursitor Doom[_4_] Electronics Repair 5 April 7th 15 05:11 AM
Bank winding of HV SMPS transformer? N_Cook Electronics Repair 2 December 12th 10 09:13 AM
SMPS capacitor test question Cydrome Leader Electronics Repair 2 July 27th 10 02:51 AM
Primary-secondary coupling capacitor in SMPS Franc Zabkar Electronics Repair 8 September 16th 06 03:06 PM


All times are GMT +1. The time now is 06:07 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"