Monitor came in with no pix symptom. Collector of HOT had 150vdc,
1200ppv with reduced frequency and a squashed waveform.

Changed Q5G1 (2SJ306) wich was short and pix came back with always
increasing brightness until shutdown.

Also changed Q2001 (A1L4M)=nte2360 witch was open but the problem
remains the same.

Flyback rings OK with R5U1 lifted and HOT tests good. On techforce's
advice changed HOT and B+ is now stable.

Picture now has hourglass shape and there is no user control of pin
or width.



  #2   Report Post  
techforce
 
Posts: n/a
Default NEC JC-1571 w. no width or pin control

NTE2359 = A1L4M

One is PNP other is NPN.

Replace HOT With Original (or a Very Close Sub) at the same time as with a
NEW FET. Try 2SJ307. The Key Is Replacing the 2 parts at the Same time,
because one can degrade the other.


"RobertDubord" wrote in message
...
Monitor came in with no pix symptom. Collector of HOT had 150vdc,
1200ppv with reduced frequency and a squashed waveform.

Changed Q5G1 (2SJ306) wich was short and pix came back with always
increasing brightness until shutdown.

Also changed Q2001 (A1L4M)=nte2360 witch was open but the problem
remains the same.

Flyback rings OK with R5U1 lifted and HOT tests good. On techforce's
advice changed HOT and B+ is now stable.

Picture now has hourglass shape and there is no user control of pin
or width.





  #3   Report Post  
RobertDubord
 
Posts: n/a
Default NEC JC-1571 w. no width or pin control

From what I could understand, A1L4M=AN1L4M=NTE2360 PNP, but then I
could be mistaken.

I will change the 2SJ307 and see what happens.


"techforce" a écrit dans le message news:
...
NTE2359 = A1L4M

One is PNP other is NPN.

Replace HOT With Original (or a Very Close Sub) at the same time as with a
NEW FET. Try 2SJ307. The Key Is Replacing the 2 parts at the Same time,
because one can degrade the other.


"RobertDubord" wrote in message
...
Monitor came in with no pix symptom. Collector of HOT had 150vdc,
1200ppv with reduced frequency and a squashed waveform.

Changed Q5G1 (2SJ306) wich was short and pix came back with always
increasing brightness until shutdown.

Also changed Q2001 (A1L4M)=nte2360 witch was open but the problem
remains the same.

Flyback rings OK with R5U1 lifted and HOT tests good. On techforce's
advice changed HOT and B+ is now stable.

Picture now has hourglass shape and there is no user control of pin
or width.







  #4   Report Post  
RobertDubord
 
Posts: n/a
Default NEC JC-1571 w. no width or pin control

Changed 2SJ306 for 2SJ307 and no change. At 1024x768 resolution,
collector of HOT reads 75VDC, 1134PPV at 34.9675kHz. This seems O.K.
Still have hourglass and width control problem. ie. can't adjust
these while other adjustments work well.


"RobertDubord" a écrit dans le message news:
...
From what I could understand, A1L4M=AN1L4M=NTE2360 PNP, but then I
could be mistaken.

I will change the 2SJ307 and see what happens.


"techforce" a écrit dans le message news:
...
NTE2359 = A1L4M

One is PNP other is NPN.

Replace HOT With Original (or a Very Close Sub) at the same time as with

a
NEW FET. Try 2SJ307. The Key Is Replacing the 2 parts at the Same time,
because one can degrade the other.


"RobertDubord" wrote in message
...
Monitor came in with no pix symptom. Collector of HOT had 150vdc,
1200ppv with reduced frequency and a squashed waveform.

Changed Q5G1 (2SJ306) wich was short and pix came back with always
increasing brightness until shutdown.

Also changed Q2001 (A1L4M)=nte2360 witch was open but the problem
remains the same.

Flyback rings OK with R5U1 lifted and HOT tests good. On

techforce's
advice changed HOT and B+ is now stable.

Picture now has hourglass shape and there is no user control of

pin
or width.









Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
OT What is happening to the gun control movement? Gunner Metalworking 21 May 27th 04 02:14 AM
Cop revolt against gun control Gunner Metalworking 0 October 27th 03 03:00 AM
Drilling metal control panel advice... Alan Kamrowski II Metalworking 14 October 25th 03 05:08 AM
Smartheat Economy7 Control System Darren Sellers UK diy 5 October 23rd 03 08:52 PM


All times are GMT +1. The time now is 11:22 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"