Default David Eden WT800 amp, 2010 date, blows mains fuses

Sometimes after 1.5 hours originally , now sometimes soon after switch on ,
sometimes a bit later.
Amp plate says 5A(T) for 240V use. Inside the IEC, is one non-blown 2A(T) in
the active position, ah! the simplest of repair jobs, BUT
No reported noises like magnetisation buzz or speaker noises , no smoke or
smells. Owner uses the same cab and speaker wire with another amp ok.
No blown fuses retained by the owner but reported to be blackened. 2A fuses
passing 3A or so and then failing when asked to pass 4A say, but they will
have fuse-wire breaks , not vaporisation and blackening.
Tx torroid 0.8R or so per primary , measured cold, seems reasonable for
135mm diameter, 65mm high Tx. Not in a position to check the main caps yet ,
but no bulges.
Any Eden usual suspects? PbF and RoHS stickers a-plenty


  #2   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 170
Default David Eden WT800 amp, 2010 date, blows mains fuses

N_Cook presented the following explanation :
Sometimes after 1.5 hours originally , now sometimes soon after switch on ,
sometimes a bit later.
Amp plate says 5A(T) for 240V use. Inside the IEC, is one non-blown 2A(T) in
the active position, ah! the simplest of repair jobs, BUT
No reported noises like magnetisation buzz or speaker noises , no smoke or
smells. Owner uses the same cab and speaker wire with another amp ok.
No blown fuses retained by the owner but reported to be blackened. 2A fuses
passing 3A or so and then failing when asked to pass 4A say, but they will
have fuse-wire breaks , not vaporisation and blackening.
Tx torroid 0.8R or so per primary , measured cold, seems reasonable for
135mm diameter, 65mm high Tx. Not in a position to check the main caps yet ,
but no bulges.
Any Eden usual suspects? PbF and RoHS stickers a-plenty


English punctuation would help understnd your giberish. B-)

And I think this has been said before. Are you a certified slow leaner?

--
John G


  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 5,247
Default David Eden WT800 amp, 2010 date, blows mains fuses

At least the 25A triac is for mains-on soft start, not some sort of crowbar.
Still not got to the caps yet. At least most of the schema for a version of
these amps is out there





  #4   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 187
Default David Eden WT800 amp, 2010 date, blows mains fuses

On May 15, 9:59*am, John G wrote:
N_Cook presented the following explanation :

Sometimes after 1.5 hours originally , now sometimes soon after switch on ,
sometimes a bit later.
Amp plate says 5A(T) for 240V use. Inside the IEC, is one non-blown 2A(T) in
the active position, ah! the simplest of repair jobs, BUT
No reported noises like magnetisation buzz or speaker noises , no smoke or
smells. Owner uses the same cab and speaker wire with another amp ok.
No blown fuses retained by the owner but reported to be blackened. 2A fuses
passing 3A or so and then failing when asked to pass 4A say, but they will
have fuse-wire breaks , not vaporisation and blackening.
Tx torroid 0.8R or so per primary , measured cold, seems reasonable for
135mm diameter, 65mm high Tx. Not in a position to check the main caps yet ,
but no bulges.
Any Eden usual suspects? PbF and RoHS stickers a-plenty


English punctuation would help understnd your giberish. B-)

And I think this has been said before. Are you a certified slow leaner?

--
John G


A bit like that famous tower in Pisa?
  #5   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 5,247
Default David Eden WT800 amp, 2010 date, blows mains fuses

Blackened pcb under R10 and R11 discoloured bands but reading 3R3 each ,pcb
charring 30M DVM probing and goes from 20V Tx secondary to 1000uF 10V cap
so unlikely a mains fuse KO
Anodes of the valve go via ok MPSA92 to the ps , but may replace the 2x 160V
10uF caps in that area.
Just leaves the 2x paralleled 3 , main caps 100V 10000uF. Other than
separating and heating and measuring ESR (not necessarily related to
self-curing internal flash-over) , nothing else left to explore?
If its recovering interlayer discharge inside the Tx then can't do anything
about that, any sort of tell-tale for that scenario? presumably add fuses
would 10 amp blow before the 5A mains fuse with failing electro?) to the
power rail secondaries




  #6   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 5,247
Default David Eden WT800 amp, 2010 date, blows mains fuses

Heavy engineering job as a solid block of snap-in 6 Jamicon , 85 deg C,
LS, 809K(M) 100V 10,000uF.
Presumably failing because the contact verticals between are filled with
filled silicone rubber and hotmelt glue in the 2 central gaps and 85 deg C
ratings.
someone's internal view of similar amp
http://ivanrichards.files.wordpress.....jpg?w=150&h=1
12
1500W hot air gun to break the solder and binding of the most amenable set
of Cs for wedges under then completed with a 100W soldering iron : 4oz board
, wide traces and both sides of the pcb.
No oily messes on the pcb but only one cap end is dry, 4 have an oily film
and one has that plus drops.
Expensive set of replacement 105deg C ones plus try and get some through
ventilation, perhaps the replacements set at an angle to form a sort of duct
and a small fan or as in line with the amp fan perhaps a duct only . And
hope not an on-going internal Tx problem
Cold ESR of each is good and warmed to whatever a minute of low setting hot
air gun gets them to , no noticeable ESR change.
I suppose the only test would be a current limited 100V supply , resistor
and voltmeter to monitor implied leakage current and heating each cap .


  #7   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 5,247
Default David Eden WT800 amp, 2010 date, blows mains fuses

Cooked all 6 at 85 deg C, with thermometer in the middle of the block, for
at least 30min and then applied 110 volt DC to each in turn, all charged up
and held for 30 seconds or so and discharged normally and equally, while
still at 85 deg C.
But not too pleasant electrolyte smell in the room. Orientation of the caps
was up the other way from useage and no vibration. I wanted one to show some
obvious problem.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
The Chronicles of NARNIA: The Voyage of the Dawn Treader 2010 -- GOTHACKED Before the Release of the Date baptist Metalworking 0 November 25th 10 09:32 AM
Shallow Well Pump Blows Fuses frank1492 Home Repair 6 September 2nd 10 04:54 PM
Sony TV blows fuses [email protected] Electronics Repair 4 March 8th 07 01:44 PM
12 amp a/c (2001) blows 15a type sl fuses? [email protected] Home Repair 14 July 28th 06 07:16 PM
RCA 36" TV blows fuses David G. Electronics Repair 2 February 16th 04 12:44 AM


All times are GMT +1. The time now is 01:12 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"