Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 10
Default Philips CD-670 (CDM2/10 transport) sometime fails the startupsequence, ...sometime not.

It has a CDM2 transport driven by TDA 5708 and TDA 5709. I think it is
the famous Philips original control board...
At the end of the drawer closing procedure it sometime reads the TOC
correctly. Sometime not. Same turning it on or pressing play with a CD
in.
When the startup sequence is successfull (TOC content correctly
reported on display) it plays two/three tracks, ...then fails.
When the startup sequence is successfull I can start palying at track
1 or 21 it always works for some time.
When palying some noise comes out the transport: it seems the pickup
is scraping the disk;
When failing sometime (not all the times) the arm swings and badly
beats at enf-of-route.

My conclusions a
drawer motor and gear ok;
laser ok;
focus ok;
tracking ok;
pickup ribbon investigated checked ok;
not ripple found in any of the power lines.
CAPS on the control board all measure "normal" ESR (normal means
"compared with new bees I have");
May be the laser power is low... is there anybody able to describe a
correct procedure to check and tune the laser power?
Emanuele.

  #2   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 10
Default Philips CD-670 (CDM2/10 transport) sometime fails the startupsequence, ...sometime not.

On 29 Set, 20:24, Emanuele Girlando wrote:
It has a CDM2 transport driven by TDA 5708 and TDA 5709. I think it is
the famous Philips original control board...
At the end of the drawer closing procedure it sometime reads the TOC
correctly. Sometime not. Same turning it on or pressing play with a CD
in.
When the startup sequence is successfull (TOC content correctly
reported on display) it plays two/three tracks, ...then fails.
When the startup sequence is successfull I can start palying at track
1 or 21 it always works for some time.
When palying some noise comes out the transport: it seems the pickup
is scraping the disk;
When failing sometime (not all the times) *the arm swings and badly
beats at enf-of-route.

My conclusions a
drawer motor and gear ok;
laser ok;
focus ok;
tracking ok;
pickup ribbon investigated checked ok;
not ripple found in any of the power lines.
CAPS on the control board all measure "normal" ESR (normal means
"compared with new bees I have");
May be the laser power is low... is there anybody able to describe a
correct procedure to check and tune the laser power?
Emanuele.


an update:
raplaced 33uF cap close to tda5708. No change.
I ask it again: what is the correct procedure for measuring and tuning
the laser power?
  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 10
Default Philips CD-670 (CDM2/10 transport) sometime fails the startupsequence, ...sometime not.

On 1 Ott, 09:11, Emanuele Girlando wrote:
On 29 Set, 20:24, Emanuele Girlando wrote:



It has a CDM2 transport driven by TDA 5708 and TDA 5709. I think it is
the famous Philips original control board...
At the end of the drawer closing procedure it sometime reads the TOC
correctly. Sometime not. Same turning it on or pressing play with a CD
in.
When the startup sequence is successfull (TOC content correctly
reported on display) it plays two/three tracks, ...then fails.
When the startup sequence is successfull I can start palying at track
1 or 21 it always works for some time.
When palying some noise comes out the transport: it seems the pickup
is scraping the disk;
When failing sometime (not all the times) *the arm swings and badly
beats at enf-of-route.


My conclusions a
drawer motor and gear ok;
laser ok;
focus ok;
tracking ok;
pickup ribbon investigated checked ok;
not ripple found in any of the power lines.
CAPS on the control board all measure "normal" ESR (normal means
"compared with new bees I have");
May be the laser power is low... is there anybody able to describe a
correct procedure to check and tune the laser power?
Emanuele.


an update:
raplaced 33uF cap close to tda5708. No change.
I ask it again: what is the correct procedure for measuring and tuning
the laser power?


..... swapping the CDM2 with another working unit. No change.
The control board of the palyer I have picked out the test CDM2 from
is different. It has two trimpots: one for laser power and the other
for focus offset.....

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Philips CD960 transport belts? Paul[_18_] Electronics Repair 12 August 1st 08 12:41 AM
what grease/oil to lubricate vcr transport? [email protected] Electronics Repair 4 February 27th 08 05:33 PM
Problem connecting Philips TV to Philips Sound System via HDMI Uncle Dave Electronics Repair 4 November 8th 06 02:58 AM
What will you say with Service Manuals provided by Philips for Philips DVD and Recorders Myauk Electronics Repair 1 October 19th 06 01:53 PM
OT - Boat Transport Mike Metalworking 4 March 23rd 06 01:06 AM


All times are GMT +1. The time now is 12:45 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"