Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

 
 
LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #16   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 6,772
Default Burning out an intermittant heater-cathode short in a CRT


"Wiebe Cazemier" wrote in message
b.home.nl...
On Sunday 04 May 2008 02:54, Wiebe Cazemier wrote:
Thanks for your elaborate response.

I just had a revelation today, which also sheds light not only on this
issue,
but also with earlier issues I had with this monitor; that being that it
turned brighter and brighter over time, resulting in a very washed out
picture with visible retrace lines, when at default settings. The OSD
menu
allowed me to decrease cut-off and gain, but at some point that wasn't
enough
anymore, and I needed to decrease G2 value on the flyback. And now I
think I
know what's going on.

I think a leakage path between the cathodes and G1 has slowly been
forming,
which slowly increased beam current over the years, and therefore
brightness.
Now, I'm at a point where there is not just leakage, but a dead short now
and
again. Tapping therefore, will not solve the issue.

Another problem I had, was that the automatic color calibrator didn't
correct
for the washed out picture. And I suspect that is because the cathodes
pulled
the extra current directly from ground, and therefore the circuit which
measures the beam current was oblivious to it. However, this is just
speculation.

I think I will need a proper CRT rejuvenator to clear the leakage path
between cathode and G1. I could do it myself, by using the G2 voltage for
example, but googling reveals that modern CRTs are too fragile for this,
and
that professional rejuvenators are matched precisely for modern tubes.

It also appears that cathode-G1 shorts are one of the easier things to
fix,
so I think I can still avoid buying a TFT . The only thing is, that it
would be better to let a professional servicer do it, but I dread the
likely
outcome of it coming back with a calibration that is way off.


One more thing. I may just decide to try to fix it myself (I was planning
to
use the capacitor discharge method, starting with a few uF at about 230V
or
so). But I have a question:

Most pin-outs of CRTs I've seen, contain only one G1 pin. But the G1
connection
on this neck board connects to two pins on the CRT. And, with the socket
removed, I can also measure 0 Ohms resistance between those pins. Is it
normal
that there are two G1 pins? When zapping, should I connect them together?


Probably for no other reason than there being a 'spare' pin. If they read
zero to one another, then it's pretty safe to assume that they are both
connected to the same place. Can you not find a data sheet for the tube on
the 'net somewhere, or a schematic for the whole monitor ?
www.eserviceinfo.com might be a good place to look for one. As far as your
calibration fears go, I would suggest that when these shorts are removed, it
is going to want a good set-up anyway ...

Arfa


 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Cathode / Heater leakage. N Cook Electronics Repair 3 December 27th 07 03:00 PM
Replacement for space heater with burning smell [email protected] Home Repair 5 November 19th 05 02:02 PM
Replacement for space heater with burning smell [email protected] Home Repair 0 November 18th 05 06:46 PM
Adiabatic short-circuit compliance on very short short-circuits Will Dean UK diy 17 August 23rd 05 12:03 PM
refilling burning kerosene heater Mike Home Ownership 10 March 20th 05 03:42 AM


All times are GMT +1. The time now is 05:57 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"