Home |
Search |
Today's Posts |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
Posted to sci.electronics.repair
|
|||
|
|||
Tek 2235 no scan
subject just about says it all ,,,wih I had kept my old one.
I get 2 dots and a 1" line connecting them nothing else,,help very much appreciated. Regards, Joe Smith West Point Monitor Repair West Point, Texas 78963 |
#2
Posted to sci.electronics.repair
|
|||
|
|||
Tek 2235 no scan
joesmith wrote:
subject just about says it all ,,,wih I had kept my old one. I get 2 dots and a 1" line connecting them nothing else,,help very much appreciated. That sounds just like the beam finder on many Tek models. -- Dec. 6 (Bloomberg) -- Government officials and activists flying to Bali, Indonesia, for the United Nations meeting on climate change will cause as much pollution as 20,000 cars in a year. |
#3
Posted to sci.electronics.repair
|
|||
|
|||
Tek 2235 no scan
clifto wrote in :
joesmith wrote: subject just about says it all ,,,wih I had kept my old one. I get 2 dots and a 1" line connecting them nothing else,,help very much appreciated. That sounds just like the beam finder on many Tek models. or the horiz amp has a problem. ISTR that metal film resistors in the output amp overheat and change value. Also,how is the vertical trace movement? can he swing the trace to the top and bottom of the graticule? or does it limit? if so,then HV problem. BAMA has schematics for this scope or the 2236,it's close brother. -- Jim Yanik jyanik at kua.net |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
shop tech - cat scan - 07 cat scan.jpg (1/1) | Woodworking Plans and Photos | |||
shop tech - cat scan - 07 cat scan.jpg (0/1) | Woodworking Plans and Photos | |||
Focus adjustment on a Tek 2235 CRO | Electronics Repair | |||
Tektronix 2235 Fan? | Electronics Repair | |||
Tektronix 2235 Oscilloscope Troubles | Electronics Repair |