Does anyone know what the differences are between these two models of
scopes (if any)? |
#2
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]() |
#3
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
Jamie t wrote in
news ![]() wrote: Does anyone know what the differences are between these two models of scopes (if any)? if memory serves, the M is a higher BW unit. no,the 465M was a "ruggedized" scope,closer to a 455A2B2 than a regular 465;not ANYthing like a 465 WRT circuitry.No common parts. (dunno about the CRT) They both were 100Mhz scopes. And it really wasn't more rugged,IMO. I'd rather have a 465 than a 465M. -- Jim Yanik jyanik at kua.net |
#4
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]() wrote in message oups.com... Does anyone know what the differences are between these two models of scopes (if any)? 465M is the Military version. It's functionally about the same, but it looks different. |
#5
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]() no,the 465M was a "ruggedized" scope,closer to a 455A2B2 than a regular 465;not ANYthing like a 465 WRT circuitry.No common parts. (dunno about the CRT) They both were 100Mhz scopes. And it really wasn't more rugged,IMO. I'd rather have a 465 than a 465M. CRT has a different part number but it's compatible. I have a 465M CRT in my 465B and it works fine. |
#6
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
"James Sweet" wrote in
news:Zn5Vi.140$MW.14@trndny05: wrote in message oups.com... Does anyone know what the differences are between these two models of scopes (if any)? 465M is the Military version. It's functionally about the same, as are all scopes.... ;-) but it looks different. electrically,it's totally different;the 465M has one hybrid (TEK-made)IC that is the entire vertical preamp. the 465 pre-amp is discrete. I also disliked the flex of the 465M plastic case. -- Jim Yanik jyanik at kua.net |
#7
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]() 465M is the Military version. It's functionally about the same, as are all scopes.... ;-) Touché ![]() What I was getting at is the performance specs are about the same. I wasn't aware of the hybrid chips, that's as good a reason as any to avoid it. I hate scrapping an otherwise fine piece of equipment because of bad custom parts made of unobtanium. |
#8
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
"James Sweet" wrote in
news:S%7Vi.1842$BD.971@trndny06: 465M is the Military version. It's functionally about the same, as are all scopes.... ;-) Touché ![]() What I was getting at is the performance specs are about the same. I wasn't aware of the hybrid chips, that's as good a reason as any to avoid it. I hate scrapping an otherwise fine piece of equipment because of bad custom parts made of unobtanium. The 465 still has TEK-made ICs in it;the 155-0049-0x sweep logic IC,a couple of trigger amp ICs(155-0032-xx)and some have a vertical output amp IC. IIRC,the 465 was the top selling scope of all time. But there are SO many other TEK scopes that use those same ICs,they are still obtainable. -- Jim Yanik jyanik at kua.net |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Tektronix 465m - bad LV power supply? | Electronics Repair | |||
465m shorted 95V problems | Electronics Repair | |||
Tek 465M as/usm Oscilloscope Problem | Electronics Repair | |||
Tektronix 465M Scope Transistor 2SC2527 | Electronics Repair | |||
Tektronix 465M HV problem | Electronics Repair |