Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 3
Default Tektronix 465m vs 465

Does anyone know what the differences are between these two models of
scopes (if any)?

  #4   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 1,572
Default Tektronix 465m vs 465


wrote in message
oups.com...
Does anyone know what the differences are between these two models of
scopes (if any)?


465M is the Military version. It's functionally about the same, but it looks
different.


  #5   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 1,572
Default Tektronix 465m vs 465



no,the 465M was a "ruggedized" scope,closer to a 455A2B2 than a regular
465;not ANYthing like a 465 WRT circuitry.No common parts.
(dunno about the CRT)
They both were 100Mhz scopes.

And it really wasn't more rugged,IMO.
I'd rather have a 465 than a 465M.




CRT has a different part number but it's compatible. I have a 465M CRT in my
465B and it works fine.




  #6   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 3,103
Default Tektronix 465m vs 465

"James Sweet" wrote in
news:Zn5Vi.140$MW.14@trndny05:


wrote in message
oups.com...
Does anyone know what the differences are between these two models of
scopes (if any)?


465M is the Military version. It's functionally about the same,


as are all scopes.... ;-)
but it
looks different.



electrically,it's totally different;the 465M has one hybrid (TEK-made)IC
that is the entire vertical preamp. the 465 pre-amp is discrete.

I also disliked the flex of the 465M plastic case.

--
Jim Yanik
jyanik
at
kua.net
  #7   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 1,572
Default Tektronix 465m vs 465



465M is the Military version. It's functionally about the same,


as are all scopes.... ;-)



Touché

What I was getting at is the performance specs are about the same. I wasn't
aware of the hybrid chips, that's as good a reason as any to avoid it. I
hate scrapping an otherwise fine piece of equipment because of bad custom
parts made of unobtanium.


  #8   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 3,103
Default Tektronix 465m vs 465

"James Sweet" wrote in
news:S%7Vi.1842$BD.971@trndny06:



465M is the Military version. It's functionally about the same,


as are all scopes.... ;-)



Touché

What I was getting at is the performance specs are about the same. I
wasn't aware of the hybrid chips, that's as good a reason as any to
avoid it. I hate scrapping an otherwise fine piece of equipment
because of bad custom parts made of unobtanium.




The 465 still has TEK-made ICs in it;the 155-0049-0x sweep logic IC,a
couple of trigger amp ICs(155-0032-xx)and some have a vertical output amp
IC.
IIRC,the 465 was the top selling scope of all time.

But there are SO many other TEK scopes that use those same ICs,they are
still obtainable.

--
Jim Yanik
jyanik
at
kua.net
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Tektronix 465m - bad LV power supply? gabeschine Electronics Repair 4 September 6th 07 10:16 AM
465m shorted 95V problems Steve Electronics Repair 14 May 17th 07 10:46 AM
Tek 465M as/usm Oscilloscope Problem yoda439 Electronics Repair 6 January 20th 05 06:58 PM
Tektronix 465M Scope Transistor 2SC2527 Mark Electronics Repair 4 August 31st 04 05:23 PM
Tektronix 465M HV problem Steve Turner Electronics Repair 12 February 23rd 04 01:50 AM


All times are GMT +1. The time now is 10:11 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"