Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 59
Default Schematic manual for a Fluke 6070A sig gen

Hi All
As per subject really. I have the user manual and service manual, but I need
the schematics to debug a start-up issue.
This unit has been out of support for 12 years. But it is (well, it was!) a
damn good unit.


  #2   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 272
Default Schematic manual for a Fluke 6070A sig gen

"Grumps" wrote in message
...
Hi All
As per subject really. I have the user manual and service manual, but I need
the schematics to debug a start-up issue.
This unit has been out of support for 12 years. But it is (well, it was!) a
damn good unit.



You can buy a copy of the schematics manual for this unit from:
http://www.manualsplus.com

It ain't cheap!!!

--
Dave M
MasonDG44 at comcast dot net (Just substitute the appropriate characters in the
address)

"In theory, there isn't any difference between theory and practice. In
practice, there is." - Yogi Berra


  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 85
Default Schematic manual for a Fluke 6070A sig gen

"DaveM" wrote in message
...
"Grumps" wrote in message
...
Hi All
As per subject really. I have the user manual and service manual, but I
need the schematics to debug a start-up issue.
This unit has been out of support for 12 years. But it is (well, it was!)
a damn good unit.



You can buy a copy of the schematics manual for this unit from:
http://www.manualsplus.com

It ain't cheap!!!


Thanks for the link. It's only $60. And if that keeps it going for years to
come, it'll be worth it. A 500MHz sig gen of this spec costs much more than
$60!

The unit has started working again after taking it apart and re-seating a
few cables. Fingers crossed.


  #4   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 129
Default Schematic manual for a Fluke 6070A sig gen

On Oct 16, 2:59 am, "Grumps" wrote:

The unit has started working again after taking it apart and re-seating a
few cables. Fingers crossed.


You might look over the front panel IC's. I seem to remember one
important IC tended to work loose due to the heat sink tab under it.




  #5   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 85
Default Schematic manual for a Fluke 6070A sig gen

"Ancient_Hacker" wrote in message
oups.com...
On Oct 16, 2:59 am, "Grumps" wrote:

The unit has started working again after taking it apart and re-seating a
few cables. Fingers crossed.


You might look over the front panel IC's. I seem to remember one
important IC tended to work loose due to the heat sink tab under it.


Thanks.

I had the front panel apart and re-seated all of those ICs too.
I did notice one sitting on a metal tab. Looked a bit of a bodge to me. And
the IC didn't have a good contact with the tab, nor had an exposed metal
bottom!

There are two axial electrolytics on one board. Very gentle pressure on the
pcb actually causes one of them to touch another smaller board (which is
mostly ground). I don't think that was the problem, but I've trimmed its
leads so that won't happen again.

The first problem I had with this unit (about two years ago) was that it
would only start in certain orientations. This turned out to be caused by
the oven oscillator not starting up. I had to disassemble this, and found
that the power wire was wrapped around its pin, but had never actually been
soldered. It just rested like that for 15 years!




  #6   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 129
Default Schematic manual for a Fluke 6070A sig gen

Yep this is a very complicated signal generator. One weak area is the
"noise reduction loop". Hundreds of parts, scads of exotic parts,
dozens of critical adjustments, about half of them not documented in
any of the manuals. You were supposed to send the unit to Fluke for
those adjustments. If you have a working unit, lucky you.




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Fluke 8810A service manual or schematics JW Electronics Repair 1 June 9th 07 07:23 AM
service manual for fluke 6071a seb Electronics Repair 0 January 23rd 07 12:47 AM
Manual for Fluke 382A Tweetldee Electronics Repair 3 December 28th 04 03:31 AM
Fluke DMM model 77 series I and II schematic request Jacques Carrier Electronics Repair 4 September 20th 04 11:55 AM