Panasonic 32" TV fuse blowing.
Model # CT32SL13. This set has the "common" fuse blown at turn on due
to too much inrush current at degaussing. I don't have the part number for the "kit". Nothing on the Panasonic site. Looking for the part number of the upgrade parts. Thanks, Dani. |
#2
Posted to sci.electronics.repair
|
|||
|
|||
Panasonic 32" TV fuse blowing.
On May 17, 8:38 pm, Dani wrote:
Model # CT32SL13. This set has the "common" fuse blown at turn on due to too much inrush current at degaussing. I don't have the part number for the "kit". Nothing on the Panasonic site. Looking for the part number of the upgrade parts. Thanks, Dani. change the degauss posistor. -B |
#3
Posted to sci.electronics.repair
|
|||
|
|||
Panasonic 32" TV fuse blowing.
On 18 May, 00:21, b wrote:
On May 17, 8:38 pm, Dani wrote: Model # CT32SL13. This set has the "common" fuse blown at turn on due to too much inrush current at degaussing. I don't have the part number for the "kit". Nothing on the Panasonic site. Looking for the part number of the upgrade parts. Thanks, Dani. change the degauss posistor. -B I agree with the last answer! Very common. Could be the degausing coils, but not very commen! Rod |
#4
Posted to sci.electronics.repair
|
|||
|
|||
Panasonic 32" TV fuse blowing.
BTW original fuse is a 6.3 amp rating, normally a 6.5 will work fine as a
replacment but as suggested change the DGS Posistor. wrote in message ups.com... On 18 May, 00:21, b wrote: On May 17, 8:38 pm, Dani wrote: Model # CT32SL13. This set has the "common" fuse blown at turn on due to too much inrush current at degaussing. I don't have the part number for the "kit". Nothing on the Panasonic site. Looking for the part number of the upgrade parts. Thanks, Dani. change the degauss posistor. -B I agree with the last answer! Very common. Could be the degausing coils, but not very commen! Rod |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
CRT TV Blowing fuse | Electronics Repair | |||
Spotlights blowing fuse problem? | UK diy | |||
Storage heater blowing fuse? | UK diy | |||
Toro Mower Keeps Blowing Fuse | Home Ownership | |||
Immersion Heater Fuse Blowing | UK diy |