Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 3
Default wierd optical sled behavior on Alpine car audio 6-disk CD changer

I have an Alpine CHM-S630 6-disk CD changer that is giving me grief.

The unit selects each CD properly from the magazine, but as soon as it
loads it into place, the optical sled slams out to the full extent of
the limits of the track, out to the extreme edge of the CD diameter.
It never appears to go to the center of the CD, and it never takes a
read from the disk.

After the sled hits the track limit, then for about 2 seconds, the
worm & roller mechanism keeps trying to push the sled out through the
side of the case, resulting in a horrible grinding noise as the
plastic block on the sled strips itself against the "worm" screw,
since the sled can't move any farther.

After about 2 seconds elapse, the unit gives up and stops trying to
push the sled past the limit of the track. Another 2 seconds after
that, the unit gives up on spinning the CD, and the CD comes to a
halt.

This happens every time the unit loads a CD.

I've tried cleaning the lens on the sled, but it doesn't seem to be an
optical problem. It doesn't seem to be a mechanical problem, either.
The worm & roller for sled movement works just fine - the problem is
that for some reason, the unit is telling the sled to slam out past
the limits of its track. I'm stumped.

Can anyone point me in the right direction for a fix?

Thanks.

  #2   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 98
Default wierd optical sled behavior on Alpine car audio 6-disk CD changer

wrote:
I have an Alpine CHM-S630 6-disk CD changer that is giving me grief.

The unit selects each CD properly from the magazine, but as soon as it
loads it into place, the optical sled slams out to the full extent of
the limits of the track, out to the extreme edge of the CD diameter.
It never appears to go to the center of the CD, and it never takes a
read from the disk.

After the sled hits the track limit, then for about 2 seconds, the
worm & roller mechanism keeps trying to push the sled out through the
side of the case, resulting in a horrible grinding noise as the
plastic block on the sled strips itself against the "worm" screw,
since the sled can't move any farther.

After about 2 seconds elapse, the unit gives up and stops trying to
push the sled past the limit of the track. Another 2 seconds after
that, the unit gives up on spinning the CD, and the CD comes to a
halt.

This happens every time the unit loads a CD.

I've tried cleaning the lens on the sled, but it doesn't seem to be an
optical problem. It doesn't seem to be a mechanical problem, either.
The worm & roller for sled movement works just fine - the problem is
that for some reason, the unit is telling the sled to slam out past
the limits of its track. I'm stumped.

Can anyone point me in the right direction for a fix?

Thanks.


It sounds like the "home" switch or sensor is stuck or damaged, making
the unit think the sled is stuck at the center of the disc and making it
constantly try to move the laser away from the center.
I would look for a broken switch or the tab that activates it.
Good luck.
  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 3
Default wierd optical sled behavior on Alpine car audio 6-disk CD changer

Thanks for the idea.

I tested the "home" switch for the sled with my multimeter, dialed in
to the 200K ohm setting. It's just an ordinary (tiny) spring-loaded
two-position pin switch.

With the switch pressed in (ie. sled is at center of CD hub), I get no
resistance (00.0 on the multimeter display). But with the switch
released (ie. sled is anywhere *except* right at the center), I get a
reading of 47.8 on the multimeter display. These results are both
using the 200K scale setting on the ohmmeter.

I would have expected infinite resistance, not 47.8, with the switch
released. So that's a bit surprising. The switch isn't perfectly
open when the pin is released, although there's obviously much more
resistance than when the pin is pressed in.

Do you think there is inadequate resistance with the switch released,
or would 47.8 a normal result for this kind of switch?

I'd love the problem to be a bad switch, but Murphy's Law says I can't
get off this easily.

Thanks.


On Apr 12, 12:10 pm, Jumpster Jiver wrote:
wrote:
I have an Alpine CHM-S630 6-disk CD changer that is giving me grief.


The unit selects each CD properly from the magazine, but as soon as it
loads it into place, the optical sled slams out to the full extent of
the limits of the track, out to the extreme edge of the CD diameter.
It never appears to go to the center of the CD, and it never takes a
read from the disk.


After the sled hits the track limit, then for about 2 seconds, the
worm & roller mechanism keeps trying to push the sled out through the
side of the case, resulting in a horrible grinding noise as the
plastic block on the sled strips itself against the "worm" screw,
since the sled can't move any farther.


After about 2 seconds elapse, the unit gives up and stops trying to
push the sled past the limit of the track. Another 2 seconds after
that, the unit gives up on spinning the CD, and the CD comes to a
halt.


This happens every time the unit loads a CD.


I've tried cleaning the lens on the sled, but it doesn't seem to be an
optical problem. It doesn't seem to be a mechanical problem, either.
The worm & roller for sled movement works just fine - the problem is
that for some reason, the unit is telling the sled to slam out past
the limits of its track. I'm stumped.


Can anyone point me in the right direction for a fix?


Thanks.


It sounds like the "home" switch or sensor is stuck or damaged, making
the unit think the sled is stuck at the center of the disc and making it
constantly try to move the laser away from the center.
I would look for a broken switch or the tab that activates it.
Good luck.


  #4   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 9
Default wierd optical sled behavior on Alpine car audio 6-disk CD changer

With the switch pressed in (ie. sled is at center of CD hub), I get no
resistance (00.0 on the multimeter display). But with the switch
released (ie. sled is anywhere *except* right at the center), I get a
reading of 47.8 on the multimeter display. These results are both
using the 200K scale setting on the ohmmeter.


I would have expected infinite resistance, not 47.8, with the switch
released. So that's a bit surprising. The switch isn't perfectly
open when the pin is released, although there's obviously much more
resistance than when the pin is pressed in.


Did you disconnect the switch when you tested it? If not, then you
are reading whatever it is connected to when it is open...

--
Dunfield Development Services http://www.dunfield.com
Low cost software development tools for embedded systems
Software/firmware development services Fax:613-256-5821

  #5   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 3
Default wierd optical sled behavior on Alpine car audio 6-disk CD changer

You're right, I did not disconnect the switch before the test. So
there's the reason that I don't get infinite resistance when it's
open. Thanks.

So the implication is that the switch is working properly, I guess. I
suppose I could desolder the switch and double check, but since I get
0 resistance when it's depressed, and the resistance increases when
it's released, it appears to be working properly.

Anything else worth checking? I hate seeing this thing turn into an
expensive paperweight.

Thanks.

On Apr 12, 5:23 pm,
(Dave Dunfield) wrote:
With the switch pressed in (ie. sled is at center of CD hub), I get no
resistance (00.0 on the multimeter display). But with the switch
released (ie. sled is anywhere *except* right at the center), I get a
reading of 47.8 on the multimeter display. These results are both
using the 200K scale setting on the ohmmeter.
I would have expected infinite resistance, not 47.8, with the switch
released. So that's a bit surprising. The switch isn't perfectly
open when the pin is released, although there's obviously much more
resistance than when the pin is pressed in.


Did you disconnect the switch when you tested it? If not, then you
are reading whatever it is connected to when it is open...

--
Dunfield Development Services http://www.dunfield.com
Low cost software development tools for embedded systems
Software/firmware development services Fax:613-256-5821





  #6   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 81
Default wierd optical sled behavior on Alpine car audio 6-disk CD changer

Hello,

While I don't know the Alpine car units at all, I've seen some Sony
single disc home players do this when one of the clocks (oscillators)
fails. If left there making that awful noise, it will damage the rack
gear on the optical pick up, by grinding the teeth off it.

Seeing this will require powering the unit on a work bench with an
oscilloscope, and probably a service manual. I don't work on car audio
stuff myself.

Regards,
Tim Schwartz
Bristol Electronics




wrote:
I have an Alpine CHM-S630 6-disk CD changer that is giving me grief.

The unit selects each CD properly from the magazine, but as soon as it
loads it into place, the optical sled slams out to the full extent of
the limits of the track, out to the extreme edge of the CD diameter.
It never appears to go to the center of the CD, and it never takes a
read from the disk.

After the sled hits the track limit, then for about 2 seconds, the
worm & roller mechanism keeps trying to push the sled out through the
side of the case, resulting in a horrible grinding noise as the
plastic block on the sled strips itself against the "worm" screw,
since the sled can't move any farther.

After about 2 seconds elapse, the unit gives up and stops trying to
push the sled past the limit of the track. Another 2 seconds after
that, the unit gives up on spinning the CD, and the CD comes to a
halt.

This happens every time the unit loads a CD.

I've tried cleaning the lens on the sled, but it doesn't seem to be an
optical problem. It doesn't seem to be a mechanical problem, either.
The worm & roller for sled movement works just fine - the problem is
that for some reason, the unit is telling the sled to slam out past
the limits of its track. I'm stumped.

Can anyone point me in the right direction for a fix?

Thanks.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
No Display Alpine Car radio 7863 [email protected] Electronics Repair 3 November 6th 05 07:55 PM
Alpine car amp model:3548 [email protected] Electronics Repair 1 July 6th 05 02:47 PM
need schematic car radio ALPINE 7281L Miroslav Koscica Electronics Repair 0 June 9th 05 12:54 PM
Spins too fast! Alpine CD changer boredwild Electronics Repair 10 December 23rd 04 07:59 PM
Schematics for Alpine C33 Car Radio sayah Electronics Repair 0 July 30th 04 01:00 PM


All times are GMT +1. The time now is 01:49 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.