Hi there,

I have an old (13 year) B&O ME6000 television. When stereo is on, and
people hare talking, the "s"-sounds are scratchy.. When I turn into
MONO-sound the sound is perfect.

I have been told that the problem lies in the Nicam Decoder being
defect.

Anyone who knows if I can replace the old decoder myself? I am
electrician engineer... but maybee it isnt that easy???

  #2   Report Post  
Posted to sci.electronics.repair
Ole Geisler -
 
Posts: n/a
Default Replace the Nicam Decoder in B&O ME6000???

On 28 Nov 2005 08:51:49 -0800, "Tychsen" wrote:

I have been told that the problem lies in the Nicam Decoder being
defect.


Correct. Basically it is a PHILIPSGR2.4 chassis with slight
modifications, and a B&O specified IF/NICAM module. This module is no
longer available, and close to impossible to repair.

Often these faults come from bad caps (tm) on the mainboard, start
with changing ALL caps in power/deflection, and resolder the IF/NICAM
board. (in the tin can) - if no success, remove the Xtal in the
IF/NICAM box, you loose the stereo, but sound will be OK.

--
Jeg kan virkelig ikke se, hvad det skulle betyde, at forbinde en 0,1 mm X 1
mm tin-fyldt kobberbane i ét apparat med en anden 0,1 mm X 1 mm tinfyldt
kobberbane i et andet apparat, via et sølvbelagt 4 mm2 polafhængigt
højteknologisk kulfiberinfiltreret kabel til et astronomisk beløb.

Tro flytter ikke bjerge. Tro flytter kroner.
  #3   Report Post  
Posted to sci.electronics.repair
Tychsen
 
Posts: n/a
Default Replace the Nicam Decoder in B&O ME6000???

Tak Ole... det er fandme ligegyldigt hvor man spørger, så er du
der...

He he.. så mangler jeg bare, at få det oversat til dansk... :-) og
så er det frem med loddekolben...

Jeg har fået fat i servicemanualen til GR2.4, men det er ikke godt nok
vel? Der findes en specifik til ME6000 jo.. Men jeg må nok sige, at
konsollen i GR2.4-manuallen ligner ME6000 konsollen til forveksling.

Takker...

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Replace A/C when replacing furnace? Walter E. Home Repair 12 March 26th 05 12:49 PM
Major house renovation xrongor Home Repair 2 October 15th 04 01:16 AM
Replace of Heat Pump or Get new system? OKE Home Ownership 1 May 16th 04 08:51 AM
Replace of Heat Pump or Get new system? OKE Home Ownership 1 May 15th 04 07:16 PM


All times are GMT +1. The time now is 03:34 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"