Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
 
Posts: n/a
Default Reconditioning Chattering Well Water Pump Control Box Relay?

Am trying to get some info before pulling my well water pump control
box apart.

The main question is if the relay contacts can be reconditioned?

Have done some searches to see if anyone else had posted this question.
So far nothing but did come across a few interesting relay postings
like this
http://groups.google.com/group/sci.e...a4fb5fd6b6ba0d
and this
http://groups.google.com/group/rec.g...1ceae49bff2531


Have no idea what to expect when I willstart taking it apart so would
appreciate any suggestions or tips.


FYI the Pump Control Panel is a "Town & Country date code CX" mfr Red
Jacket which became part of ITT in 2001. So far I have searched but
have not been able to find a parts list for it so do not know anything
about the relay.

Thanks

Gene OHara

  #2   Report Post  
Mike Berger
 
Posts: n/a
Default

Some relay contacts can be reconditioned. You can burnish them
with a contact burnisher, and in some cases actually replace the
contact point itself. You can find identical contacts from
another relay and replace them.

Gold plated contacts cannot be burnished without ruining them.

Reconditioning contacts was common practice in arcade game
service in the electromechanical days.

wrote:
Am trying to get some info before pulling my well water pump control
box apart.

The main question is if the relay contacts can be reconditioned?

Have done some searches to see if anyone else had posted this question.
So far nothing but did come across a few interesting relay postings

  #3   Report Post  
James Sweet
 
Posts: n/a
Default


wrote in message
ups.com...
Am trying to get some info before pulling my well water pump control
box apart.

The main question is if the relay contacts can be reconditioned?



Anything *can* be reconditioned, but for something like this it's only worth
trying if you absolutely can't find a suitable replacement. You should be
able to get a new contactor for under $20, www.usamfg.com might have
something suitable, or ebay.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Detergents and cleaners FAQ [email protected] UK diy 49 September 25th 05 11:34 PM
Water Pump / Pressure Tank Problem !!!!!! James Nipper Home Repair 9 June 28th 04 02:13 AM
Priming the Water Pump frank Home Repair 21 May 2nd 04 03:12 AM
NO MORE hot water problems [email protected] Home Repair 9 January 29th 04 06:15 PM
Thankless or Tankless hot water heaters [email protected] Home Repair 6 January 29th 04 03:01 AM


All times are GMT +1. The time now is 10:09 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us