Default Anybody have service info for Eizo (Nanao) monitors?

I have a 21" Eizo T962, with a horizontal problem.
Background without signal is purple and will sync fine with DOS screen.
But starting with windows logo, it goes totally sideways and starts rolling
from bottom to top.
Pressing the Auto resize turns off picture and standby starts to flash
rapidly.

It seems to be impossible to find any schema's or service info on these
monitors.

Jan
Finland


  #2   Report Post  
JANA
 
Posts: n/a
Default

There is no service information or replacement parts available from the
manufacture.

Most of the time, the failures are many of the electrolytic capacitors
become high in ESR over time and use. Use an ESR meter, and test all the
capacitors in the monitor, especially in the scan (H & V) amplifiers. This
should include the blanking circuits, CRT drive circuits, and the HV
generator circuits.

In these monitors, as for the picture turning purple in the background, this
is usually attributed to the CRT starting to go weak.

--

JANA
_____


"JMK" wrote in message
.. .
I have a 21" Eizo T962, with a horizontal problem.
Background without signal is purple and will sync fine with DOS screen.
But starting with windows logo, it goes totally sideways and starts rolling
from bottom to top.
Pressing the Auto resize turns off picture and standby starts to flash
rapidly.

It seems to be impossible to find any schema's or service info on these
monitors.

Jan
Finland



  #3   Report Post  
JMK
 
Posts: n/a
Default


"JANA" wrote in message
...
There is no service information or replacement parts available from the
manufacture.

Most of the time, the failures are many of the electrolytic capacitors
become high in ESR over time and use. Use an ESR meter, and test all the
capacitors in the monitor, especially in the scan (H & V) amplifiers. This
should include the blanking circuits, CRT drive circuits, and the HV
generator circuits.

In these monitors, as for the picture turning purple in the background,

this
is usually attributed to the CRT starting to go weak.

--

JANA
_____


"JMK" wrote in message
.. .
I have a 21" Eizo T962, with a horizontal problem.
Background without signal is purple and will sync fine with DOS screen.
But starting with windows logo, it goes totally sideways and starts

rolling
from bottom to top.
Pressing the Auto resize turns off picture and standby starts to flash
rapidly.

It seems to be impossible to find any schema's or service info on these
monitors.

Jan
Finland



Well, that's interesting policy for a company. I'll be sure not to buy (or
recommend) their products again to anybody. ;-(

Anyway, thanks for the info. :-)

Jan
Finland


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
MONITOR, TV, VCR, LAPTOP, PRINTER SCHEMATICS AND SERVICE MANUALS Hymie Electronics Repair 0 February 3rd 05 09:21 AM
WTD: Service info for Fluke 900 test fixture John Robertson Electronics Repair 0 December 15th 04 06:58 PM
33" computer monitor repair Bo S. Electronics Repair 2 September 19th 04 12:22 PM
Crown C600 TV - service info needed john Electronics Repair 8 July 18th 03 01:54 AM


All times are GMT +1. The time now is 08:23 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"